401521069 | Form 17 | 1/15/2018 | 1/22/2018 | | 113 | GAS | -- | 1 | WHISPER | -- | -- | Yes | -- | -- | Surface casing produced no fluids. Blew down surface casing an extra 30 min ended with a whisper. Surface casing shut in for 15 min ended with 3 PSI. Both tubing and casing were LOTO.
|
401351831 | Form 17 | 7/5/2017 | 7/24/2017 | | 154 | GAS | -- | 1 | WHISPER | -- | -- | No | -- | -- | SC PRODUCED CONDENSATE. BLEW DOWN AND ADDITIONAL 30 MINS, ENDED AT A WHISPER. SHUT IN FOR 15 MINS, BUILT UP TO 65 PSI. TUBING AND CASING WERE SHUT IN UPON ARRIVAL. |
401252623 | Form 17 | 2/24/2017 | 4/6/2017 | | 365 | GAS | -- | 243 | GAS | 328 | 330 | No | -- | -- | SURFACE CSG PRODUCED NO FLUIDS. BLEW DOWN SURFACE CSG FOR AN EXTRA 30 MINUTES; ENDED WITH 178 PSI. SHUT IN SURFACE CSG FOR 15 MIN.; ENDED WITH 215 PSI.
|
400292408 | Form 17 | 4/23/2012 | 6/5/2012 | PLUNGER LIFT | 239 | GAS | -- | 36 | GAS | 232 | 238 | No | -- | -- | No fluid was produced during 30 minute blow down |