Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-045-19629GGU Federal
34D-29-691
TEP ROCKY MOUNTAIN LLC
96850
PR
4/1/2011
MAMM CREEK
52500
GARFIELD  045
NWSE 29 6S91W 6
417787
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 784 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404214357Form 175/19/20255/22/2025CLOCK/INTERMITTER158CONTINUOUS GAS0 NO FLOW 9092No----This is an annual bradenhead test that was performed on day six of the seven-day shut-in period due to the bradenhead exceeding the threshold pressure. The bradenhead is connected to the flow line with an approved pressure management plan. The test was performed through a 2 inch valve.
403804840Form 175/28/20245/28/2024CLOCK/INTERMITTER164CONTINUOUS GAS0 WHISPER 125126No----This is an annual bradenhead test that was performed on Day Six of the seven-day shut-in period due to the bradenhead exceeding the threshold pressure. The bradenhead is connected to the flow line with an approved pressure management plan. The test was performed through a 2 inch valve.
Click for SpecificsFull6/21/20237/17/2023Clock/Intermitter60N/A--60N/A12362NoNoNotied in to sales
Click for SpecificsFull3/14/20224/18/2022Clock/Intermitter68N/A--68N/A146136NoNoNotied into tubing
Click for SpecificsFull6/30/20217/12/2021Shut-In107N/A--0Down to Zero219225NoNoNoTied into flow line.
402317736Form 172/19/20202/20/2020SHUT-IN152GAS --0 DOWN TO 0 598217No---- 
Click for SpecificsLight6/19/20196/2/2020 44  0 ----NoNoNo 
Click for SpecificsLight5/9/20176/2/2020 46  0 ----NoNoNo 
Click for SpecificsLight6/15/20166/2/2020 45  0 ----NoNoNo 
2221315Form 171/12/20111/20/2011FLOWING157DOWN TO 0 --0 NO FLOW 00YesYesNoTUBING AND PRODUCTION CASING PRESSURES NOT REPORTED BY THE OPERATOR FOR THIS TEST. ACTUAL PRESSURES UNKNOWN, BUT ZERO WAS ENTERED FOR THE PRODUCTION CASING PRESSURE TO PROCESS THIS FORM AND AVOID FORM 17 VALIDATION ERRORS. OPERATOR COMMENTS: BRADENHEAD SHUT-IN PRESSURE AFTER 48 HOURS BUILT TO 150 PSI. PER BLM INSTRUCTION, THE BRADENHEAD WAS OPENED AT THIS POINT AND THEN SHUT BACK IN ON 1/10/2011. ON THE MORNING OF 1/12/2011, THE BRADENHEAD PRESSURE WAS 157 PSI. THE VALVE WAS THEN FULLY OPENED TO BLOW DOWN THE PRESSURE. THE GAS VENTED FOR APPROXIMATELY 1 MINUTE AND 39 SECONDS BEFORE REACHING 0 PSI. AT THE END OF THE BRADENHEAD TEST, THE BRADENHEAD VALVE WAS LEFT OPEN TO VENT.
Click for SpecificsLight10/14/20106/2/2020 --  0 ----NoNoNo 
Click for SpecificsLight10/2/20106/2/2020 --  -- ----NoNoNo