| 404209283 | Form 17 | 5/13/2025 | 5/19/2025 | CLOCK/INTERMITTER | 205 | CONTINUOUS | GAS | 0 | NO FLOW | 101 | 102 | No | -- | -- | This is an annual bradenhead test that was performed on day one of the seven-day shut-in period due to the bradenhead exceeding the threshold pressure. The bradenhead is connected to the flow line with an approved pressure management plan. The test was performed through a 2 inch valve. |
| 403791387 | Form 17 | 5/14/2024 | 5/15/2024 | CLOCK/INTERMITTER | 197 | CONTINUOUS | GAS | 0 | WHISPER | 65 | 89 | No | -- | -- | This is an annual bradenhead test that was performed on Day One of the seven-day shut-in period due to the bradenhead exceeding the threshold pressure. The bradenhead is connected to the flow line with an approved pressure management plan. The test was performed through a 2 inch valve. |
| Click for Specifics | Full | 6/21/2023 | 7/17/2023 | Clock/Intermitter | 63 | N/A | -- | 63 | N/A | 63 | 73 | No | No | No | tied into sales |
| Click for Specifics | Full | 3/15/2022 | 4/18/2022 | Clock/Intermitter | 79 | N/A | -- | 79 | N/A | 108 | 113 | No | No | No | tied into tubing |
| Click for Specifics | Full | 6/16/2021 | 7/12/2021 | Shut-In | 80 | N/A | -- | 0 | Down to Zero | 123 | 131 | No | No | No | Tied into flow line. |
| 402086088 | Form 17 | 6/20/2019 | 6/24/2019 | PLUNGER LIFT | 150 | GAS | -- | 0 | DOWN TO 0 | 243 | 243 | No | -- | -- | |
| Click for Specifics | Light | 6/19/2019 | 6/2/2020 | | 150 | | | -- | | -- | -- | No | No | No | |
| 401680860 | Form 17 | 6/20/2018 | 6/22/2018 | PLUNGER LIFT | 188 | WATER H20 | -- | 0 | VAPOR | 230 | 239 | No | -- | -- | |
| 401280301 | Form 17 | 5/10/2017 | 5/11/2017 | PLUNGER LIFT | 156 | WATER H20 | -- | 0 | NO FLOW | 200 | 201 | No | -- | -- | |
| Click for Specifics | Light | 5/9/2017 | 6/2/2020 | | 196 | | | -- | | -- | -- | No | No | No | |
| 401064228 | Form 17 | 6/16/2016 | 6/17/2016 | SHUT-IN | 205 | GAS | -- | 0 | NO FLOW | 216 | 216 | No | -- | -- | |
| Click for Specifics | Light | 6/15/2016 | 6/2/2020 | | 196 | | | -- | | -- | -- | No | No | No | |
| 400948412 | Form 17 | 12/4/2015 | 12/4/2015 | SHUT-IN | 195 | GAS | -- | 0 | WHISPER | 212 | 213 | No | -- | -- | blew to 0 psi in 13 minutes 27 seconds |
| Click for Specifics | Light | 9/18/2000 | 6/2/2020 | | 0 | | | 0 | | -- | -- | No | No | No | |