Click for Specifics | Full | 4/12/2024 | 4/16/2024 | | 2 | Down to Zero | -- | 0 | Down to Zero | 679 | 676 | No | No | No | Annual Test. 2 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy. |
403307869 | Form 17 | 1/20/2023 | 1/31/2023 | FLOWING | 32 | DOWN TO 0 | MUD | 0 | NO FLOW | 2605 | 2572 | Yes | -- | -- | Automation alert follow-up test. 32 PSI mud on open, collected 40mL BH and production liquid sample. Produced 1 cup and died to drip. Drip stopped at 7 minute mark. No flow for remainder of test. |
403265356 | Form 17 | 12/19/2022 | 12/19/2022 | FLOWING | 40 | DOWN TO 0 | GAS | 0 | NO FLOW | 2330 | 2329 | No | -- | -- | Post-Production within 60 days of first sales. 40 PSI blew down to 0 PSI within first minute of test, no pressure or flow observed for the remainder of the test. |
403095631 | Form 17 | 7/1/2022 | 7/5/2022 | SHUT-IN | 0 | NO FLOW | -- | 0 | NO FLOW | 0 | 0 | No | -- | -- | Initial Test Post Rig Release. 0 PSI, no pressure or flow observed for the entire 30 min test. PDC will monitor pressure and re-test according to bradenhead policy. |