Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-001-10095B-Farm LD
18-034HN
PDC ENERGY INC
69175
PR
12/1/2022
WATTENBERG
90750
ADAMS  001
NENW 7 1S67W 6
452914
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1719 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
403753567Form 174/12/20244/15/2024PLUNGER LIFT103DOWN TO 0 WATER AND GAS0 CONTINUOUS 320326No----Abatement system follow up test. 103 PSI water and gas flow blew down to 0 PSI within first minute of test. Fluid trickled for entire test, ~1/2 gallon total. PDC will monitor pressure and re-test according to bradenhead policy.
403416000Form 175/29/20235/30/2023PLUNGER LIFT4CONTINUOUS WATER AND GAS0 NO FLOW 385387No----Abatement system follow up test. 4 PSI water and gas flow blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will submit sundry with bradenhead details as soon as possible. PDC will continue to monitor monthly.
403263439Form 1712/15/202212/16/2022SHUT-IN84DOWN TO 0 WATER AND GAS0 CONTINUOUS 157157Yes----Automation Alert follow-up test. 84 PSI gas and water blew down to 0 PSI in seconds. 1 cup fluid at open, then steady drip for remainder of test. PDC will schedule a sampling event and submit results via form 43. PDC will continue to monitor monthly.
403191687Form 1710/6/202210/10/2022PLUNGER LIFT116DOWN TO 0 GAS0 NO FLOW 326326Yes----Automation Alert test. 116 PSI gas blew down to 0 PSI in five minutes with no flow or pressure for the remainder of the test. PDC will schedule a sampling event and submit results via form 43. PDC will continue to monitor monthly.
403094927Form 176/29/20227/1/2022PLUNGER LIFT143DOWN TO 0 GAS0 NO FLOW 441441No----Test after pressure discovery. Gaseous on open for 3 seconds and died. Unable to collect sample due to lack of volume. Water drips after 30 seconds. Attempted to collect water sample. BH only produced ~ 80mL of water and died. No flow for remainder of test.
402858726Form 1710/22/202111/1/2021FLOWING23DOWN TO 0 GAS0 NO FLOW 239238No----Test after displacement and build up since 10/6/2021. Gas for 18 seconds at open then dead for remainder of test.
402798259Form 178/26/20218/31/2021FLOWING105DOWN TO 0 GAS0 NO FLOW 208205No----Retest after displacement and build up. Gas for 10 seconds at open. Then dead for remainder of test.
402299915Form 171/21/20201/30/2020FLOWING146WATER H20 --0 WATER H20 979975No----Test after 5 week blowdown and 1 week buildup. Blew down to drip instantaneously. Made ~1 cup of water during test. Still not enough to take sample.
402137628Form 178/5/20198/8/2019SHUT-IN64NO FLOW --0 WATER H20 00No----Test per NTO. Made 1 cup (8 oz) of water and died. Water drip at 15 min mark. Made a total of 9 oz of water.
401629036Form 175/1/20185/3/2018FLOWING30NO FLOW --0 NO FLOW 17221722No----Test taken within 30 days of DOFP. Bled down to 0 in less than 10 seconds
401551344Form 172/24/20182/28/2018SHUT-IN24DOWN TO 0 --0 NO FLOW 00No----