Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-001-09941Anderson
18-3-11HC
PDC ENERGY INC
69175
PR
1/1/2024
WATTENBERG
90750
ADAMS  001
SWSW 18 1S66W 6
441824
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1540 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
403764145Form 174/15/20244/22/2024SHUT-IN12DOWN TO 0 GAS0 NO FLOW 406406No----Remediation follow up test. 12 PSI gas blew down to 0 PSI within first 95 seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
403377781Form 174/14/20234/19/2023PLUNGER LIFT236CONTINUOUS GAS0 WHISPER 412398Yes----Annual Test. 236 PSI gas flow blew down to 0 PSI in 30 minutes. PDC will schedule a sampling event and submit results via form 43. PDC will continue to monitor monthly.
403112349Form 177/11/20227/21/2022PLUNGER LIFT123DOWN TO 0 GAS0 WHISPER 386378YesYes--test after pressure discovery. Gas on open, collected BH and prod. sample. Down to 0 in 45 seconds. Whisper for 5 minutes and died to almost undetectable vapor for remainder of test.
402800557Form 178/27/20219/2/2021PLUNGER LIFT46DOWN TO 0 GAS0 NO FLOW 430425No----Test per NTO. Gas on open, down to whisper in 30 seconds, died in 2 minutes. No flow for remainder of test.
Click for SpecificsLight10/28/20202/22/2021 0 --0No Flow351361NoNoNo 
402527588Form 1710/28/202011/6/2020FLOWING47CONTINUOUS GAS0 NO FLOW 385385YesYesNoTest after blow down period. Last blowdown 7/31/2020. Gas at open down to whisper at 1 minute. Vapor at 2 minutes. Dead at 9 minutes. Returned to sample on 11/4/2020
402151063Form 178/20/20198/20/2019FLOWING525CONTINUOUS --0 WHISPER 615611YesYes--Test per NTO. BH had 525 psi on open and was continuous until the 25 min mark where it was a whisper. Samples taken off of BH and CSG. Shut in pressure was 0 psi. No fluid.