Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-001-09900Ivey LC
02-033HC
PDC ENERGY INC
69175
PA
4/14/2025
WATTENBERG
90750
ADAMS  001
SWSE 11 1S68W 6
442411
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 2021 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404127451Form 172/27/20253/13/2025SHUT-IN0NO FLOW NONE0 NO FLOW 00No----Pre-P&A. 0 PSI, with no flow observed for 30 minutes.
404131026Form 172/20/20253/17/2025SHUT-IN0NO FLOW NONE0 NO FLOW 7500No----Pre-P&A. 0 PSI, with no flow observed for 30 minutes.
403846517Form 176/28/20247/8/2024PLUNGER LIFT32CONTINUOUS WATER AND GAS12 CONTINUOUS 642642No----Annual test. 32 PSI blew down to 12 PSI in 30 minutes, continuous gas and water flow, ~10 gallons total fluid. PDC will monitor pressure and re-test according to bradenhead policy.
403618476Form 1712/6/202312/7/2023FLOWING102CONTINUOUS WATER AND MUD0 CONTINUOUS 726725No----Abatement system follow up test. 102 PSI water and mud flow blew down to 0 PSI in 30 minutes. ~2 gallon fluid at open, steady trickle for remainder of test, ~4 gallons total. PDC will monitor pressure and re-test according to bradenhead policy.
403444715Form 176/22/20236/26/2023FLOWING52CONTINUOUS WATER AND GAS0 CONTINUOUS 811811No----Abatement system follow up test. 52 PSI water and gas flow flow blew down to 0 PSI within first minute of test. Greyish fluid with resin trickled the entire test. PDC will submit sundry with bradenhead details as soon as possible. PDC will continue to monitor monthly.
Click for SpecificsFull8/29/20229/6/2022 37Down to Zero--0Down to Zero10751075NoNoneNone 
402833099Form 1710/5/202110/6/2021FLOWING48DOWN TO 0 GAS0 NO FLOW 23672366No----Test after DOFP. Gas on open for 1 minute and 30 seconds and died. No flow for remainder of test.
402679587Form 174/29/20215/4/2021SHUT-IN75DOWN TO 0 GAS0 WHISPER 00YesYes--Test prior to toe-prep/frac. Gas on open, died to whisper in 1 minute and 30 seconds. Whisper for remainder of test. BH gas sample collected.