View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404225747Form 175/13/20256/2/2025PLUNGER LIFT6CONTINUOUS GAS0 NO FLOW 952952No----Remediation follow up test. 6 PSI gas blew down to 0 PSI within five minutes of test. No pressure or flow observed for the remainder of the test. Operator will monitor pressure and re-test according to bradenhead policy.
403931868Form 179/23/20249/24/2024FLOWING70CONTINUOUS GAS0 WHISPER 26682663No----Post-Production test within 60 days of first sales. 70 PSI gas flow blew down to 0 PSI within first minute of test, whisper gas and fluid stream for remainder of test, ~1.25 gallons total fluid. PDC will monitor bradenhead pressure monthly and submit annual test.
403701540Form 172/24/20242/28/2024SHUT-IN0NO FLOW --0 NO FLOW 00No----Initial Test Post Rig Release. 0 PSI, no pressure or flow observed for the entire 30 min test. PDC will monitor pressure and re-test according to bradenhead policy.