WELL05-123-51812Drake
20N
PDC ENERGY INC
69175
PR
9/20/2024
WATTENBERG
90750
WELD  123
SWNW 17 4N64W 6
482390
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1701 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404222607Form 175/15/20255/29/2025PLUNGER LIFT7CONTINUOUS GAS0 NO FLOW 833834No----Remediation follow up test. 7 PSI whisper blew down to 0 PSI within five minutes of test. No pressure or flow observed for the remainder of the test. Operator will monitor pressure and re-test according to bradenhead policy.
403984599Form 1711/4/202411/6/2024 40CONTINUOUS WATER AND GAS0 WHISPER 19691977No----Post-Production within 60 days of first sales. 40 PSI water and gas blew down to 0 PSI in 30 minutes, whisper gas and water observed throughout the entire test. PDC will schedule a sampling event and submit results via form 43. PDC will monitor pressure and re-test according to bradenhead policy.
403701632Form 172/24/20242/28/2024SHUT-IN0NO FLOW --0 NO FLOW 00No----Initial Test Post Rig Release. 0 PSI, no pressure or flow observed for the entire 30 min test. PDC will monitor pressure and re-test according to bradenhead policy.