Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-123-51782George
03NA
PDC ENERGY INC
69175
PR
11/25/2024
WATTENBERG
90750
WELD  123
SWNE 21 4N64W 6
482391
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 2017 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404245753Form 175/30/20256/18/2025PLUNGER LIFT2CONTINUOUS GAS0 NO FLOW 10151051No----Remediation follow up test. 2 PSI gas flow blew down to 0 PSI within five minutes of test. No pressure or flow observed for the remainder of the test. Operator will monitor pressure and re-test according to bradenhead policy
404008818Form 1711/18/202411/26/2024FLOWING87CONTINUOUS WATER AND GAS0 WHISPER 23262337No----Post-Production within 60 days of first sales. 87 PSI water and gas blew down to 0 PSI in 30 minutes, water trickle and whisper gas observed for entire test, ~1 gal. PDC will schedule a sampling event and submit results via form 43. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull6/17/20246/25/2024 0No Flow--0No Flow00NoNoNoInitial Test Post Rig Release.  0 PSI, no pressure or flow observed for the entire 30 min test. PDC will monitor pressure and re-test according to bradenhead policy.