Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-123-51584Raindance FC
23-289HNX
PDC ENERGY INC
69175
PR
5/1/2024
WATTENBERG
90750
WINDSOR/WELD  123
NENE 30 6N67W 6
427917
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 2063 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
Click for SpecificsFull7/17/20247/29/2024 4Down to Zero--0No Flow581589NoNoNoAnnual Test.  4 PSI, with no pressure or flow observed for the entire 30-minute test.  PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull5/4/20235/15/2023 3Down to Zero--0Down to Zero683677NoNoneNoneAnnual Test. 3 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
403264432Form 1712/16/202212/19/2022FLOWING98DOWN TO 0 GAS AND LIQUID HYDROCARBON0 NO FLOW 739737Yes----Automation Alert follow-up. 98 PSI gas and fluid blew down to 0 PSI within first minute of test. 2 gallons of fluid the first 40 seconds, then steady trickle for next 2 minutes, then slow drip until 4 minute mark. Fluid began again at 13 minute mark and ended at 27 minute mark. ~2.5 gallon dark fluid. PDC will schedule a sampling event and submit results via form 43. PDC will continue to monitor monthly.
403005396Form 174/1/20224/5/2022FLOWING3DOWN TO 0 GAS0 NO FLOW 19611961No----Test after DOFP. Whisper on open for 2 minutes and died. No flow for remainder of test.
402867573Form 1711/2/202111/10/2021SHUT-IN0NO FLOW NONE0 NO FLOW 00No----Test prior to toe prep/frac. Vacuum on open for 40 seconds.