Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-123-51452Bost Farm
9C-8-L
PDC ENERGY INC
69175
PR
11/18/2022
WATTENBERG
90750
GREELEY/WELD  123
Lot2 7 5N66W 6
456832
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1657 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404399929Form 1710/13/202510/22/2025PLUNGER LIFT72DOWN TO 0 WATER H200 CONTINUOUS 529531No----Remediation follow up test. 72 PSI gas and water, blew down to 0 within first few seconds, water continued for entire test. Operator will schedule a sampling event and submit results via form 43. Operator will monitor pressure and re-test according to bradenhead policy.
404020698Form 1712/6/202412/9/2024PLUNGER LIFT86CONTINUOUS WATER AND GAS0 WHISPER 570558No----Remediation follow up test. 86 PSI continuous gas and water flow blew down to 0 PSI within thirty minutes. PDC will schedule a sampling event and submit results via form 43. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull10/15/202410/22/2024 6Continuous--0No Flow595590NoNoNoAnnual Test.  6 PSI blew down to 0 PSI within first few seconds of test.  No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull12/13/202312/18/2023Flowing38Down to Zero--0Down to Zero858857NoNoNoAnnual Test. 38 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
403250076Form 1712/1/202212/5/2022FLOWING118DOWN TO 0 MUD0 NO FLOW 20592100Yes----30 days of first sales - high pressure follow-up. 118 PSI mud and gas flow blew down to 0 PSI within 5 minutes. Mud on open, produced ~1 gallon and died to drip, 1.25 gallons total. Well pad SI at 13 minute mark and BH flow ceased shortly after. PDC collected 40mL sample and will submit results via form 43. PDC will monitor pressure and re-test according to bradenhead policy.
403076372Form 176/10/20226/13/2022SHUT-IN0NO FLOW --0 NO FLOW 00No----Initial Test Post Rig Release. 0 PSI, no pressure or flow observed for the entire 30 min test. PDC will monitor pressure and re-test according to bradenhead policy.