| 404409252 | Form 17 | 10/16/2025 | 10/27/2025 | PLUNGER LIFT | 18 | DOWN TO 0 | GAS | 0 | NO FLOW | 435 | 436 | No | -- | -- | Remediation follow up test. 18 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. Operator will monitor pressure and re-test according to bradenhead policy. |
| 403976567 | Form 17 | 10/28/2024 | 10/30/2024 | PLUNGER LIFT | 6 | DOWN TO 0 | GAS | 0 | NO FLOW | 569 | 570 | No | -- | -- | Remediation follow up test. 6 PSI gas flow blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy. |
| Click for Specifics | Full | 12/13/2023 | 12/18/2023 | Flowing | 6 | Down to Zero | -- | 0 | Down to Zero | 749 | 745 | No | No | No | Annual Test. 6 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy. |
| 403271417 | Form 17 | 12/19/2022 | 12/27/2022 | FLOWING | 81 | DOWN TO 0 | WATER H20 | 0 | CONTINUOUS | 2284 | 2283 | Yes | -- | -- | Post-Production within 30 days of first sales. 81 PSI water on open, produced 100mL and died to trickle. Trickle for remainder of test. PDC will continue to monitor monthly. |
| 403076361 | Form 17 | 6/10/2022 | 6/13/2022 | SHUT-IN | 0 | NO FLOW | -- | 0 | NO FLOW | 0 | 0 | No | -- | -- | Initial Test Post Rig Release. 0 PSI, no pressure or flow observed for the entire 30 min test. PDC will monitor pressure and re-test according to bradenhead policy. |