| 404409304 | Form 17 | 10/16/2025 | 10/27/2025 | PLUNGER LIFT | 18 | DOWN TO 0 | GAS | 0 | NO FLOW | 465 | 469 | No | -- | -- | Remediation follow up test. 18 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. Operator will monitor pressure and re-test according to bradenhead policy. |
| 403976584 | Form 17 | 10/28/2024 | 10/30/2024 | PLUNGER LIFT | 8 | DOWN TO 0 | GAS | 0 | NO FLOW | 429 | 428 | No | -- | -- | Remediation follow up test. 8 PSI gas flow blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy. |
| 403799376 | Form 17 | 5/16/2024 | 5/21/2024 | FLOWING | 26 | DOWN TO 0 | WATER H20 | 0 | CONTINUOUS | 488 | 486 | No | -- | -- | Annual test. 26 PSI gas flow blew down to 0 PSI in seconds, water started to drip at 15 minute mark and continued for remainder of test, ~1/2 quart total. Fluid quantity insufficient to collect sample. PDC will monitor pressure and re-test according to bradenhead policy. |
| 403291182 | Form 17 | 1/11/2023 | 1/16/2023 | FLOWING | 58 | DOWN TO 0 | WATER H20 | 0 | CONTINUOUS | 1730 | 1730 | Yes | -- | -- | Automation Alert follow-up. 58 PSI, gas on open for less than 1 second. Water drip/trickle started at 10 minute mark for remainder of test producing ~750mL of water total. Displaced after test and collected water sample. |
| 403265333 | Form 17 | 12/16/2022 | 12/19/2022 | FLOWING | 2 | DOWN TO 0 | GAS | 0 | NO FLOW | 2186 | 2185 | No | -- | -- | Post-Production within 60 days of first sales. 2 PSI blew down to 0 PSI within first minute of test, no pressure or flow observed for the remainder of the test. |
| 403076381 | Form 17 | 6/10/2022 | 6/13/2022 | SHUT-IN | 0 | NO FLOW | -- | 0 | NO FLOW | 0 | 0 | No | -- | -- | Initial Test Post Rig Release. 0 PSI, no pressure or flow observed for the entire 30 min test. PDC will monitor pressure and re-test according to bradenhead policy. |