Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-123-50261Bost Farm
12C-11-L
PDC ENERGY INC
69175
PR
8/1/2025
DJ HORIZONTAL CODELL
16948
GREELEY/WELD  123
NWSW 7 5N66W 6
456832
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1811 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404413093Form 1710/20/202510/28/2025PLUNGER LIFT246DOWN TO 0 WATER H200 CONTINUOUS 395395No----Remediation follow up test. 246 PSI gas and water, blew down to 0 within first few seconds, water continued for entire test. Operator will schedule a sampling event and submit results via form 43. Operator will monitor pressure and re-test according to bradenhead policy.
403973254Form 1710/28/202410/29/2024SHUT-IN0NO FLOW --0 NO FLOW 133133No----Remediation follow up test. 0 PSI, no pressure or flow observed. PDC will monitor pressure and re-test according to bradenhead policy.
403527176Form 179/7/20239/12/2023PLUNGER LIFT24CONTINUOUS WATER H200 NO FLOW 477475No----Abatement system follow up test. 24 PSI water and gas flow blew down to 0 PSI within first minute of test. Black fluid dripped for 20 minutes. No pressure or flow observed for the remainder of the test. PDC will submit sundry with bradenhead details as soon as possible. PDC will continue to monitor monthly.
403264421Form 1712/16/202212/19/2022PLUNGER LIFT91DOWN TO 0 GAS AND LIQUID HYDROCARBON0 NO FLOW 576583Yes----Automation Alert follow-up test. 91 PSI gas and fluid blew down to 0 PSI within first 5 minutes of test. 1 gallon of fluid the first 2 minutes, then steady drip for next minute of test. No pressure or flow observed for the remainder of the test. PDC will schedule a sampling event and submit results via form 43. PDC will continue to monitor monthly.
Click for SpecificsFull1/28/20222/21/2022 6Down to Zero--0Down to Zero662703NoNoNo 
Click for SpecificsFull8/17/202111/1/2021 0No Flow--0No Flow944973NoNoneNone 
402518219Form 1710/16/202010/26/2020FLOWING7DOWN TO 0 --0 NO FLOW 15391539No----Post production test 7 PSI blew down to 0 PSI within seconds, no pressure or flow observed for the remainder of the test.
402930480Form 1710/6/20201/19/2022FLOWING7DOWN TO 0 --0 NO FLOW 15391539No----Post Production within 60 days of first sales, 7 PSI blew down to 0 PSI within first minute of test, no pressure or flow observed for the remainder of the test. PDC will monitor bradenhead pressure monthly and submit annual test. (Submitted as part of PDC's ongoing Bradenhead Clean-Up)
402237987Form 1711/8/201911/13/2019SHUT-IN0NO FLOW --0 NO FLOW 00No----No fluid, vapor or gas.