Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-123-47659Bost Farm
30N-11A-L
PDC ENERGY INC
69175
PR
4/23/2020
DJ HORIZONTAL NIOBRARA
16950
GREELEY/WELD  123
NWNW 7 5N66W 6
456832
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1803 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404399854Form 1710/13/202510/22/2025PLUNGER LIFT12DOWN TO 0 GAS0 NO FLOW 304305No----Remediation follow up test. 12 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. Operator will monitor pressure and re-test according to bradenhead policy.
403976395Form 1710/29/202410/30/2024PLUNGER LIFT18DOWN TO 0 GAS0 NO FLOW 377385No----Remediation follow up test. 18 PSI gas flow blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull12/13/202312/18/2023Plunger Lift12Down to Zero--0Down to Zero435432NoNoNoAnnual Test. 12 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
403214264Form 1710/31/202211/1/2022FLOWING16DOWN TO 0 GAS0 NO FLOW 540539No----Abatement system follow up test. 16 PSI gas flow blew down to 0 PSI within first minute of test through 1/2" needle valve. No pressure or flow observed for the remainder of the test. PDC will submit sundry with bradenhead details as soon as possible. PDC will continue to monitor monthly. Sample collected 2/15/2022. For wellbore diagram, see doc# 402896499.
403115432Form 177/19/20227/25/2022FLOWING13DOWN TO 0 GAS0 NO FLOW 572572No----Abatement system follow up test, 13 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will submit sundry with bradenhead details when due in 11/2022. Sample collected 2/15/2022. PDC will continue to monitor monthly. For wellbore diagram, see doc# 402896499.
403052602Form 175/17/20225/18/2022GAS LIFT54CONTINUOUS GAS0 NO FLOW 540540No----Abatement system follow up test, 54 PSI slight gas flow blew down to 0 PSI within first minute of test. No pressure or flow observed for the remainder of the test. Sundry due 11/24/2022. PDC collected a sample 2/15/2022. PDC will continue to monitor monthly. See doc # 402896499 for Wellbore Diagram.
402943272Form 171/31/20222/1/2022PLUNGER LIFT62CONTINUOUS --2 WHISPER 612612No----Annual Test, 62 PSI whisper blew down to 2 PSI in 30 minutes. PDC will schedule a sampling event and submit results via form 43 as well as a remediation plan via sundry as soon as possible. PDC will continue to monitor monthly.
402881368Form 1711/24/202111/29/2021FLOWING55DOWN TO 0 VAPOR0 NO FLOW 656653No----Abatement system follow up test, 55 PSI vapor flow blew down to 0 PSI within first minute of test. No pressure or flow observed for the remainder of the test. PDC will submit sundry with bradenhead details as soon as possible. PDC will continue to monitor monthly.
Click for SpecificsFull8/18/202111/1/2021 0No Flow--0No Flow761763NoNoneNone 
402499316Form 179/20/20209/29/2020FLOWING82GAS --0 NO FLOW 14371437No----Post production test, 82 PSI gas flow blew down to 0 PSI within first 5 min of test no pressure or flow observed for the remainder of test. PDC will attempt to collect a sample as submit results via form 43 as soon as possible. PDC will follow up with a remediation plan via sundry.
402163658Form 178/29/20199/3/2019SHUT-IN0NO FLOW --0 NO FLOW 00No----No gas, fluid or vapor. Post-drill, pre-frac bradenhead test.