Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-123-47381Postle IC
09-022HC
PDC ENERGY INC
69175
PA
9/15/2025
WATTENBERG
90750
MEAD/WELD  123
SWNW 11 3N68W 6
433857
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1552 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404384606Form 178/7/202510/8/2025SHUT-IN8CONTINUOUS WATER H200 NO FLOW 00No----Pre-P&A. 8 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test.
404209929Form 175/1/20255/19/2025SHUT-IN133CONTINUOUS WATER AND GAS1 WHISPER 00No----Delayed Completions Test. 133 PSI gas and water blew down to 1 PSI within five minutes. Water observed for entire test, ~2 gals. Operator will collect a sample and submit results via form 43. Operator will monitor pressure and re-test according to bradenhead policy.
403991517Form 1711/6/202411/12/2024 46DOWN TO 0 WATER AND GAS0 CONTINUOUS 00No----Delayed Completions Test. 46 PSI water and gas blew down to 0 PSI within seconds, water observed throughout entire test, ~ 1/2 gal. PDC will collect a sample and submit results via form 43. PDC will monitor pressure and re-test according to bradenhead policy.
403790903Form 175/9/20245/15/2024SHUT-IN78DOWN TO 0 MUD AND GAS0 CONTINUOUS 00No----Delayed Completions Test. 78 PSI gas and fluid blew down to 0 PSI within 15 seconds. Fluid continued to trickle for 12 minutes, then dripped for the remainder of the test, ~1 gallon total fluid. PDC will monitor pressure and re-test according to bradenhead policy.
403618572Form 1712/6/202312/7/2023SHUT-IN74CONTINUOUS WATER AND GAS0 CONTINUOUS 00No----Delayed Completions Test. 74 PSI blew down to 0 PSI in 5 minutes. ~0.5 gallon fluid at open, light trickle for entire test, ~1 gallon total.
403404084Form 175/11/20235/16/2023SHUT-IN80DOWN TO 0 WATER AND GAS0 CONTINUOUS 00No----Delayed Completions Test. 80 PSI gas and water flow blew down to 0 PSI in 5 minutes. Fluid at open, steady drip for entire test.
403298118Form 171/19/20231/23/2023SHUT-IN85DOWN TO 0 WATER AND GAS0 NO FLOW 00YesYesYesPre-P&A. 85 PSI blew down to 0 PSI within first few seconds of test. 1 quart water at open, then steady drip for 4 minutes. No pressure or flow observed for the remainder of the test. PDC collected a gas and water sample on 11/15/2022.
403191755Form 1710/6/202210/10/2022SHUT-IN300CONTINUOUS WATER AND GAS0 CONTINUOUS 00Yes----Delayed Completions Test. 300 PSI gas and water flow blew down to 0 PSI within seconds, water continued for the entire test through 1/2" needle valve. PDC will collect a sample and submit results via form 43. PDC will monitor pressure and re-test according to bradenhead policy.
402857428Form 1710/27/202110/29/2021SHUT-IN15DOWN TO 0 WATER H200 NO FLOW 00No----DUC well. Test per NTO. Water on open, produced ~ 1 cup and died. No flow for remainder of test.
402468950Form 178/7/20208/17/2020SHUT-IN0NO FLOW --0 NO FLOW 00No----Test 60 days after rig release. Drilled uncompleted. Vacuum at open, then dead.