Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-123-46691J Clark
2N
PDC ENERGY INC
69175
PR
10/1/2025
WATTENBERG
90750
WELD  123
NWNE 14 5N65W 6
323242
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1680 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404323700Form 178/1/20258/20/2025PLUNGER LIFT28DOWN TO 0 GAS0 NO FLOW 353353No----Remediation follow up test. 28 PSI gas and water, blew down to 0 in ten minutes. No pressure or flow observed for remainder of test. Operator will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsLight2/2/20252/10/2025 9 --0 242243NoNoNo 
403988659Form 1711/7/202411/8/2024 83CONTINUOUS WATER AND GAS0 WHISPER 266265No----Annual Test. 83 PSI water and gas, blew down to 0 within thirty minutes of test. Whisper gas and water observed throughout entire test. PDC will schedule a sampling event and submit results via form 43. PDC will monitor pressure and re-test according to bradenhead policy.
403722904Form 173/14/20243/18/2024PLUNGER LIFT4CONTINUOUS WATER AND GAS0 NO FLOW 284287No----Annual test. 4 PSI gas and fluid flow blew down to 0 PSI in 5 minutes, no flow or pressure for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
403355051Form 173/17/20233/23/2023PLUNGER LIFT14CONTINUOUS WATER AND GAS0 NO FLOW 245246No----Annual Test. 14 PSI water and gas flow blew down to 0 PSI within first minute of test. Water continued for 10 minutes, then no flow or pressure for remainder of test. PDC will continue to monitor monthly.
Click for SpecificsFull3/14/20224/18/2022 17Down to Zero--0Down to Zero293299NoNoNo 
402815978Form 179/15/20219/20/2021PLUNGER LIFT17DOWN TO 0 --0 NO FLOW 432431No----Abatement system follow up test, 17 PSI whisper blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will submit sundry with bradenhead details as soon as possible. PDC will continue to monitor monthly.
402670102Form 174/19/20214/26/2021 120WHISPER GAS0 NO FLOW 551552Yes----Annual Test 120 PSI with continuous flow, blew down to 0 PSI after 30 min. PDC has collected a sample and will submit via 43 ASAP. PDC will follow up with a remediation plan via sundry.
402769811Form 1711/12/20208/4/2021FLOWING16DOWN TO 0 --0 NO FLOW 700700No----Abatement system follow up test, 16 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will submit sundry with bradenhead details as soon as possible. PDC will continue to monitor monthly.
402448390Form 174/27/20207/22/2020 64WATER H20 --62 WATER H20 768686No----6 month follow-up test post abatement system install. PDC will continue to monitor pressure and report any increase in pressure to COGCC.
402239536Form 1711/7/201911/14/2019FLOWING136CONTINUOUS --20 GAS 10511046YesYes--Annual Test 136 PSI continous gas flow throughout the 30 min test, 20 PSI at the end of the test. PDC has collected a gas sample and will submit results via form 43. PDC has submitted a remediation plan via sundry