Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-123-46690J Clark
6N
PDC ENERGY INC
69175
SI
3/1/2025
WATTENBERG
90750
WELD  123
NWNE 14 5N65W 6
323242
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1675 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404554629Form 172/11/20262/23/2026SHUT-IN13DOWN TO 0 WATER AND GAS0 CONTINUOUS 2525No---- 
404129148Form 172/27/20253/14/2025PLUNGER LIFT7CONTINUOUS WATER AND GAS1 CONTINUOUS 389389No----Remediation follow up test. 7 PSI continuous gas and water flow blew down to 1 PSI within thirty minutes. Gas and water observed throughout entire test, ~5 gals. Operator will schedule a sampling event and submit results via form 43. Operator will monitor pressure and re-test according to bradenhead policy.
403722355Form 173/15/20243/18/2024PLUNGER LIFT82DOWN TO 0 WATER AND GAS8 CONTINUOUS 294296No----Abatement System Follow-Up test. 82 PSI fluid flow blew down to 4 PSI in 30 minutes, slight gas on open, ~15 gallons of fluid. PDC will monitor pressure and re-test according to bradenhead policy.
403547486Form 179/27/202310/2/2023PLUNGER LIFT53CONTINUOUS WATER AND GAS0 CONTINUOUS 264275Yes----Automation Alert follow-up test. 53 PSI gas and water flow blew down to 0 PSI in 5 minutes. Water was steady stream for entire test. PDC will schedule a sampling event and submit results via form 43. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull3/13/20233/27/2023 0No Flow--0No Flow243237NoNoneNoneAnnual Test. 0 PSI, with no pressure or flow observed for the entire 30-minute test. PDC will continue to monitor monthly.
Click for SpecificsFull3/15/20224/18/2022 18Down to Zero--0No Flow345349NoNoNo 
402670223Form 172/19/20214/26/2021 100CONTINUOUS WATER H2050 CONTINUOUS 556555No----6 month follow-up test post abatement system install. PDC will continue to monitor pressure and report any increase in pressure to COGCC.
402620971Form 172/19/20213/8/2021 100CONTINUOUS GAS50 CONTINUOUS 556555No----Abatement system follow up test, 100 PSI blew down to 50. PDC will continue to monitor and re-test in 6 months. PDC will evaluate the abatement system
402407047Form 174/28/20205/27/2020 79GAS --0 DOWN TO 0 706706Yes----Annual Test 79 PSI with continuous flow, blew down to 0 PSI after 30 min. PDC has collected a sample and will submit via 43 ASAP. PDC will follow up with a remediation plan via sundry.
Click for SpecificsLight10/20/20198/18/2020 27 --0 882882NoNoNo