WELL05-123-46689J Clark
11N
PDC ENERGY INC
69175
PR
12/1/2025
WATTENBERG
90750
WELD  123
NWNE 14 5N65W 6
323242
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1674 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404554966Form 172/12/20262/23/2026SHUT-IN24DOWN TO 0 WATER AND GAS0 CONTINUOUS 374373No---- 
404129082Form 172/28/20253/14/2025PLUNGER LIFT38CONTINUOUS WATER AND GAS1 CONTINUOUS 399399No----Remediation follow up test. 38 PSI continuous gas and water flow blew down to 1 PSI within thirty minutes. Gas and water observed throughout entire test, ~5 gals. Operator will schedule a sampling event and submit results via form 43. Operator will monitor pressure and re-test according to bradenhead policy.
403728701Form 173/22/20243/22/2024PLUNGER LIFT26DOWN TO 0 WATER AND GAS0 NO FLOW 344320No----Annual test. 26 PSI water and gas flow blew down to 0 PSI in 5 minutes. Water continued to trickle for 15 minutes, no flow or pressure for remainder of test. PDC will monitor pressure and re-test according to bradenhead policy.
403350580Form 173/13/20233/20/2023PLUNGER LIFT6DOWN TO 0 WATER AND GAS0 CONTINUOUS 228228No----Annual Test. 6 PSI water and gas flow blew down to 0 PSI within first few seconds of test. Water trickled the entire test. PDC will continue to monitor monthly.
403216574Form 1711/1/202211/2/2022PLUNGER LIFT7DOWN TO 0 GAS0 NO FLOW 295297No----Abatement system follow up test. 7 PSI gas flow blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will submit sundry with bradenhead details as soon as possible. PDC will continue to monitor monthly.
402984410Form 173/14/20223/15/2022PLUNGER LIFT72CONTINUOUS WATER AND GAS0 WHISPER 238238Yes----Annual Test, 72 PSI gas and water flow blew down to 0 PSI within 30 minutes. PDC will schedule a sampling event and submit results via form 43 as well as a remediation plan via sundry as soon as possible. PDC will continue to monitor monthly.
402721608Form 174/21/20216/17/2021PLUNGER LIFT17CONTINUOUS WATER H2015 CONTINUOUS 397397No----Abatement system follow up test, 17 PSI continuous water flow blew down to 15 PSI within thirty minutes. PDC will submit sundry with bradenhead details as soon as possible. PDC will schedule a sampling event and submit results via form 43.
402871611Form 173/10/202111/16/2021PLUNGER LIFT135CONTINUOUS WATER H201 WHISPER 467467Yes----Post-production, 135 PSI water flow blew down to 1 PSI in thirty minutes. PDC will schedule a sampling event and submit results via form 43. PDC will continue to monitor monthly.
402518375Form 1710/12/202010/26/2020 59DOWN TO 0 --0 NO FLOW 749749Yes----Annual Test 59 PSI with continuous flow, blew down to 0 PSI after 30 min. PDC has collected a sample and will submit via 43 ASAP. PDC will follow up with a remediation plan via sundry.
Click for SpecificsLight4/30/20205/11/2020 15 --15 825825NoNoNo 
Click for SpecificsLight10/20/20198/18/2020 0 --0 853853NoNoNo