View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404554622Form 172/11/20262/23/2026PLUNGER LIFT18DOWN TO 0 WATER AND GAS0 CONTINUOUS 393398No---- 
404129136Form 172/27/20253/14/2025PLUNGER LIFT22CONTINUOUS WATER AND GAS1 CONTINUOUS 347350No----Remediation follow up test. 22 PSI continuous gas and water flow blew down to 1 PSI within thirty minutes. Gas and water observed throughout entire test, ~5 gals. Operator will schedule a sampling event and submit results via form 43. Operator will monitor pressure and re-test according to bradenhead policy.
403722942Form 173/14/20243/18/2024PLUNGER LIFT14DOWN TO 0 GAS4 CONTINUOUS 277273No----Annual test. 14 PSI blew down to 0 PSI within 5 minutes. Fluid started at 13 minute mark and lasted for the remainder of the 30 minute test, ending at 4 PSI. ~3 gallons total fluid. PDC will monitor pressure and re-test according to bradenhead policy.
403355055Form 173/17/20233/23/2023PLUNGER LIFT12CONTINUOUS WATER AND GAS0 NO FLOW 267267No----Annual Test. 12 PSI water and gas flow blew down to 0 PSI within first minute of test. Water continued for 10 minutes, then no flow or pressure for remainder of test. PDC will continue to monitor monthly.
Click for SpecificsFull3/14/20224/18/2022 19Down to Zero--0Down to Zero288284NoNoNo 
402721638Form 174/19/20216/17/2021PLUNGER LIFT35DOWN TO 0 WATER AND MUD0  590589No----Abatement system follow up test, 35 PSI slight water and mud flow blew down to 0 PSI within first minute of test. No pressure or flow observed for the remainder of the test. PDC will submit sundry with bradenhead details as soon as possible.
Click for SpecificsFull4/19/202111/1/2021 35Water H2O--0Gas590593NoNoneNone 
402564728Form 1712/12/202012/31/2020FLOWING65WHISPER GAS0 NO FLOW 730730No----Abatement system follow up Test, 65 PSI slight gas blew down to 0 PSI within seconds. No pressure or flow observed for the remainder of the test.
402448422Form 174/27/20207/22/2020 95WATER H20 --85 WATER H20 740739No----6 month follow-up test post abatement system install. PDC will continue to monitor pressure and report any increase in pressure to COGCC.
402244420Form 1711/20/201911/20/2019FLOWING194GAS --1 GAS 10061006YesYes--194 PSI slight gas flow blew down to 1 PSI at the end of the 30 min test. PDC has collected a sample and will submit results via form 43 as soon as possible. PDC will submit a remediation plan via sundry.