Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-123-46685J Clark
12N
PDC ENERGY INC
69175
PR
12/5/2018
WATTENBERG
90750
WELD  123
NWNE 14 5N65W 6
323242
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1675 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404554948Form 172/12/20262/23/2026PLUNGER LIFT34DOWN TO 0 WATER AND GAS0 CONTINUOUS 282283No---- 
404129090Form 172/28/20253/14/2025PLUNGER LIFT21NO FLOW NONE0 NO FLOW 381381No----Remediation follow up test. 21 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. Operator will monitor pressure and re-test according to bradenhead policy.
403684783Form 172/5/20242/12/2024PLUNGER LIFT17CONTINUOUS WATER AND GAS0 CONTINUOUS 300278No----Abatement system follow up test. 17 PSI water and gas flow blew down to 0 PSI within first few seconds of test. Fluid dripped for entire test. PDC will monitor pressure and re-test according to bradenhead policy.
403478102Form 177/25/20237/27/2023PLUNGER LIFT60CONTINUOUS WATER H200 CONTINUOUS 292297Yes----High Pressure Verification test. 60 PSI steady stream fluid at open for 30 seconds then light trickle for 9 minutes. Steady drip for remainder of test. PDC will monitor pressure and re-test according to bradenhead policy.
403350539Form 173/13/20233/20/2023PLUNGER LIFT22CONTINUOUS WATER AND GAS0 CONTINUOUS 269279No----Annual Test. 22 PSI water and gas flow blew down to 0 PSI within first few seconds of test. Water trickled the entire test. PDC will continue to monitor monthly.
Click for SpecificsFull3/14/20224/18/2022 27Down to Zero--0No Flow254266NoNoNo 
402762557Form 174/21/20217/28/2021PLUNGER LIFT34WHISPER WATER H203 WHISPER 514514No----Annual Test, 34 PSI slight water blew down to 3 PSI in thirty minutes. PDC will schedule a sampling event and submit results via form 43 as well as a remediation plan via sundry as soon as possible. PDC will continue to monitor monthly.
402762548Form 179/18/20207/28/2021FLOWING12DOWN TO 0 WATER H200  685685No----Abatement system follow up test, 12 PSI blew down to 0 PSI with water within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will submit sundry with bradenhead details as soon as possible. PDC will continue to monitor monthly.
402448682Form 174/30/20207/22/2020 159WATER H20 --150 WATER H20 752750No----6 month follow-up test post abatement system install. PDC will continue to monitor pressure and report any increase in pressure to COGCC.
402236641Form 1711/7/201911/12/2019FLOWING152WHISPER --0 NO FLOW 903903No----Annual Test 152 PSI blew down to 0 PSI within first minute of test, no pressure or flow observed for the remainder of the 30 min test. PDC will attempt to collect a sample and submit results via form 43, PDC has submitted a remediation plan via sundry