Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-123-46044Postle IC
09-302HN
PDC ENERGY INC
69175
PR
1/1/2021
WATTENBERG
90750
WELD  123
SWNW 11 3N68W 6
433857
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1528 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404266064Form 176/12/20257/2/2025GAS LIFT180CONTINUOUS WATER AND GAS1 WHISPER 858858No----Remediation follow up test. 180 PSI gas and water, blew down to1 within thirty minutes, ~1.5 gals and water continued for entire test. Operator will schedule a sampling event and submit results via form 43. Operator will monitor pressure and re-test according to bradenhead policy.
403840984Form 176/21/20246/30/2024 61DOWN TO 0 WATER AND GAS0 CONTINUOUS 302305No----Remediation follow up test. 61 PSI continuous gas and water flow blew down to 0 PSI within five minutes, slow trickle of water observed throughout entire test. PDC will schedule a sampling event and submit results via form 43. PDC will monitor pressure and re-test according to bradenhead policy.
403412434Form 175/18/20235/24/2023PLUNGER LIFT112CONTINUOUS WATER AND GAS0 CONTINUOUS 320322No----Annual test. 112 PSI water and gas flow blew down to 0 PSI in 5 minutes. Water trickled for the entire test. PDC will monitor pressure and re-test according to bradenhead policy.
403263386Form 1712/15/202212/16/2022PLUNGER LIFT44CONTINUOUS WATER AND GAS0 CONTINUOUS 358375No----Abatement system follow up test. 44 PSI water and gas flow blew down to 0 PSI within first minute of test. 1 pint fluid at start of test, steady trickle for 1 minute, then steady drip for remainder of test. PDC will submit sundry with bradenhead details as soon as possible. PDC will continue to monitor monthly.
403046011Form 175/9/20225/11/2022PLUNGER LIFT254DOWN TO 0 WATER H200 CONTINUOUS 551547Yes--YesFailed re-test. Water on open, down to zero instantly and trickle. Collected 1000mL water sample. Trickle/drip for duration, produced about 2L in total.
402867473Form 1711/5/202111/10/2021PLUNGER LIFT104DOWN TO 0 WATER H200 CONTINUOUS 793784No----Failed re-test after 10 day build up. Water on open, Produced ~ 1 cup and died to drip. Intermittent drip for duration of test, produced ~ 1-1/2 cups total. Not enough volume to sample.
402669830Form 174/15/20214/24/2021FLOWING268CONTINUOUS WATER H200 CONTINUOUS 653653YesNoYesTest per NTO. Water at open, down to trickle after 1 second. Drips at 2 minutes for remainder of test. Made 1 gallon in total.
402557587Form 1712/15/202012/18/2020SHUT-IN8DOWN TO 0 GAS0 NO FLOW 858858No----Retest. Gas for 2 seconds at open then dead.
402302132Form 171/24/20202/3/2020FLOWING100WATER H20 --0 WATER H20 843843No----Test after 5 week blowdown and 1 week buildup. Intermittent drip throughout test. Made ~ 3 quarts total.
402232252Form 1711/1/201911/6/2019FLOWING234WATER H20 --0 SURGE 11341133Yes--YesTest per NTO. Water sample taken, BH down to 0 during collection. Water trickle surge throughout test, made ~1 gallon total
401719173Form 177/25/20187/31/2018FLOWING49NO FLOW --0 NO FLOW 18371836No----Test taken within 30 days of DOFP. Blew down to whisper in less than 5 seconds. Died shortly after.
401599179Form 174/7/20184/10/2018SHUT-IN0NO FLOW --0 NO FLOW 00No----