Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-123-46040Postle IC
09-299HNX
PDC ENERGY INC
69175
PR
1/1/2021
WATTENBERG
90750
WELD  123
SWNW 11 3N68W 6
433857
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1528 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404266037Form 176/12/20257/2/2025GAS LIFT35CONTINUOUS WATER AND GAS1 WHISPER 303295No----Remediation follow up test. 35 PSI gas and water, blew down to 1 within thirty minutes, water continued for entire test, ~1 gal. Operator will schedule a sampling event and submit results via form 43. Operator will monitor pressure and re-test according to bradenhead policy.
403840978Form 176/21/20246/30/2024 44DOWN TO 0 WATER AND GAS0 CONTINUOUS 281280No----Remediation follow up test. 44 PSI continuous gas and water flow blew down to 0 PSI within five minutes, water observed throughout the entire test. PDC will schedule a sampling event and submit results via form 43. PDC will monitor pressure and re-test according to bradenhead policy.
403412430Form 175/18/20235/24/2023PLUNGER LIFT86CONTINUOUS WATER AND GAS0 CONTINUOUS 307308No----Annual test. 86 PSI water and gas flow blew down to 0 PSI in 5 minutes. Water trickled for the entire test. PDC will monitor pressure and re-test according to bradenhead policy.
403263380Form 1712/15/202212/16/2022PLUNGER LIFT22CONTINUOUS WATER AND GAS0 NO FLOW 328334No----Abatement system follow up test. 22 PSI water and gas flow blew down to 0 PSI within first minute of test. 1 qt fluid at open, then steady trickle for 1 minute, then steady drip for 15 minutes. No flow for remainder of test. PDC will submit sundry with bradenhead details as soon as possible. PDC will continue to monitor monthly.
403046035Form 175/9/20225/11/2022PLUNGER LIFT206DOWN TO 0 WATER H200 CONTINUOUS 380390Yes--YesFailed retest. Water on open, collected 1000mL sample. Down to zero instantly and intermittent drips/trickle. Water dripped for duration, produced about 1.75L total.
402867446Form 1711/5/202111/10/2021PLUNGER LIFT46DOWN TO 0 WATER H200 NO FLOW 452446No----Re-test after 10 day build up. Water on open, produced less than a quart and died. Not enough to sample. No flow for remainder of test.
402671730Form 174/16/20214/27/2021FLOWING152CONTINUOUS WATER H200 CONTINUOUS 608606YesNoYesTest per NTO. Water at open continued for entire test.
Click for SpecificsLight12/15/202012/21/2020Shut-In-5 --0No Flow980980NoNoNoTest per NTO. Vacuum for 5 seconds at open then dead.
402302128Form 171/24/20202/3/2020FLOWING339WATER H20 --0 WATER H20 842841No----Test after 5 week blowdown and 1 week buildup. Down to trickle in 30 seconds. Down to drip at 15 minute mark. ~1 gallon total during test.
402232204Form 1711/1/201911/6/2019FLOWING452WATER H20 --0 WATER H20 11701170Yes--YesTest per NTO. BH dropped to 0 PSI during sample collection and was only a trickle of water. Made ~1.5 gallons total.
401719276Form 177/25/20187/31/2018FLOWING0NO FLOW --0 NO FLOW 18201820No----Test taken within 30 days of DOFP.
401599220Form 174/7/20184/10/2018SHUT-IN0NO FLOW --0 NO FLOW 00No----