Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-123-46037Postle IC
09-342HNX
PDC ENERGY INC
69175
PR
6/30/2018
WATTENBERG
90750
WELD  123
SWNW 11 3N68W 6
433857
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1528 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404266318Form 176/12/20257/2/2025GAS LIFT60CONTINUOUS WATER AND GAS1 WHISPER 400404No----Remediation follow up test. 60 PSI gas and water, blew down to 1 in thirty minutes, water continued for entire test, ~1/2 gal. Operator will schedule a sampling event and submit results via form 43. Operator will monitor pressure and re-test according to bradenhead policy.
403840991Form 176/21/20246/30/2024 49DOWN TO 0 WATER AND GAS0 CONTINUOUS 322324No----Remediation follow up test. 49 PSI continuous gas and water flow blew down to 0 PSI within five minutes, slow trickle of water observed throughout entire test. PDC will schedule a sampling event and submit results via form 43. PDC will monitor pressure and re-test according to bradenhead policy.
403412442Form 175/18/20235/24/2023PLUNGER LIFT118CONTINUOUS WATER AND GAS0 CONTINUOUS 317314No----Annual test. 118 PSI water and gas flow blew down to 0 PSI in 5 minutes. Water trickled for the entire test. PDC will monitor pressure and re-test according to bradenhead policy.
403263391Form 1712/15/202212/16/2022PLUNGER LIFT32CONTINUOUS WATER AND GAS0 CONTINUOUS 377360No----Abatement system follow up test. 32 PSI water and gas flow blew down to 0 PSI within first minute of test. Fluid started 20 seconds after open, steady drip for entire test. PDC will submit sundry with bradenhead details as soon as possible. PDC will continue to monitor monthly.
403046026Form 175/9/20225/11/2022PLUNGER LIFT204DOWN TO 0 WATER H200 CONTINUOUS 410404Yes--YesFailed retest. Water on open, down to zero instantly and water drips. Collected 1000mL sample. Trickle/Drips for duration, produced about 1.5L
402867487Form 1711/5/202111/10/2021PLUNGER LIFT87DOWN TO 0 WATER H200 CONTINUOUS 516520No----Failed re-test after 10 day build up. Water on open, Produced 1/4 cup and died to drip. Not enough volume to sample. Intermittent drip for duration of test, produced 1/2 cup total.
402556731Form 1712/15/202012/17/2020FLOWING292CONTINUOUS WATER H200 CONTINUOUS 700696YesNoYesRetest. Water at open. Trickles and drips for entire test. Made 1 gallon total.
402302134Form 171/24/20202/3/2020FLOWING226WATER H20 --0 WATER H20 799791No----Test after 5 week blowdown and 1 week buildup. down to trickle in 3 seconds, down to drip at 10 minute mark. Made ~ 2 quarts total.
402232278Form 1711/1/201911/6/2019FLOWING415WATER H20 --0 WATER H20 10711071Yes--YesTest per NTO. BH pressure down to 0 during sample collection. Trickle of water throughout test. Made 1.5 gallons total.
401719135Form 177/25/20187/31/2018FLOWING17WHISPER --0 NO FLOW 17881788No----Test taken within 30 days of DOFP. Blew down to whisper in 1 second.
401599223Form 174/6/20184/10/2018SHUT-IN200GAS --12 GAS 00No----