| Click for Specifics | Full | 3/5/2026 | 3/16/2026 | | 0 | No Flow | -- | 0 | No Flow | 0 | 0 | No | No | No | Annual Test. 0 PSI, with no pressure or flow observed for the entire 30-minute test. Operator will monitor pressure and re-test according to bradenhead policy. |
| 404142587 | Form 17 | 3/17/2025 | 3/26/2025 | SHUT-IN | 12 | CONTINUOUS | GAS | 0 | WHISPER | 0 | 0 | No | -- | -- | Annual Test. 12 PSI gas blew down to 0 PSI within thirty minutes of test, gas observed for entire test.. Operator will schedule a sampling event and submit results via form 43. Operator will monitor pressure and re-test according to bradenhead policy. |
| 403722927 | Form 17 | 3/15/2024 | 3/18/2024 | SHUT-IN | 15 | CONTINUOUS | GAS | 0 | WHISPER | 0 | 0 | No | -- | -- | Annual test. 15 PSI whisper gas blew down to 0 PSI in 30 minutes. PDC will monitor pressure and re-test according to bradenhead policy. |
| Click for Specifics | Full | 3/29/2023 | 4/10/2023 | | 3 | Down to Zero | -- | 0 | Down to Zero | 0 | 0 | No | None | None | Annual Test. 3 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will continue to monitor monthly. |
| Click for Specifics | Full | 9/29/2022 | 10/10/2022 | | 17 | Down to Zero | -- | 0 | Down to Zero | 0 | 0 | No | None | None | |
| 402679341 | Form 17 | 4/28/2021 | 5/4/2021 | SHUT-IN | 17 | DOWN TO 0 | GAS | 0 | NO FLOW | 7 | 7 | No | -- | -- | Test per NTO. Gas on open, died at 9 minute mark, no flow for the remainder of the test. |
| 402520967 | Form 17 | 10/22/2020 | 10/28/2020 | SHUT-IN | 15 | GAS | -- | 0 | NO FLOW | 21 | 21 | No | -- | -- | Test per 2020 NTO. Gas on open, down to whisper by 5 minutes mark, died by 7 minute mark. No flow for remainder of test. |
| 402223627 | Form 17 | 10/25/2019 | 10/28/2019 | SHUT-IN | 15 | DOWN TO 0 | -- | 0 | NO FLOW | 0 | 0 | No | -- | -- | Test per NTO. Blew dead through a 2" ball valve < 5 secs. BH dead |
| 402223604 | Form 17 | 10/25/2019 | 10/28/2019 | SHUT-IN | 15 | DOWN TO 0 | -- | 15 | NO FLOW | 0 | 0 | No | -- | -- | Test per NTO. Blew dead through 2 " ball valve < 5 secs. BH dead |
| 402223588 | Form 17 | 10/25/2019 | 10/28/2019 | SHUT-IN | 15 | DOWN TO 0 | -- | 0 | NO FLOW | 0 | 0 | Yes | -- | -- | Test per NTO. Blew dead through 2' ball valve < 5 secs. BH dead |
| 401664195 | Form 17 | 6/6/2018 | 6/6/2018 | SHUT-IN | 0 | NO FLOW | -- | 0 | NO FLOW | 0 | 0 | No | -- | -- | Test taken after DOFP. Bradenhead Dead. |
| 401496493 | Form 17 | 12/27/2017 | 1/2/2018 | SHUT-IN | 0 | NO FLOW | -- | 0 | NO FLOW | 0 | 0 | No | -- | -- | |