403879655 | Form 17 | 7/31/2024 | 8/7/2024 | PLUNGER LIFT | 42 | CONTINUOUS | WATER AND GAS | 21 | CONTINUOUS | 366 | 369 | No | -- | -- | Annual test. 42 PSI continuous water and gas flow blew down to 21 PSI in 30 minutes, ~5 gallons of fluid total. PDC will monitor pressure and re-test according to bradenhead policy. |
Click for Specifics | Full | 9/19/2023 | 9/25/2023 | Plunger Lift | 2 | Down to Zero | -- | 0 | Down to Zero | 413 | 410 | No | No | No | Annual Test. 2 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy. |
403194127 | Form 17 | 9/6/2022 | 10/11/2022 | PLUNGER LIFT | 34 | DOWN TO 0 | GAS | 1 | CONTINUOUS | 383 | 383 | Yes | -- | -- | Annual Test. 34 PSI gas flow blew down to 1 PSI in 30 minutes. Water started at 25 minutes. PDC collected a sample 8/2/2022. PDC will continue to monitor monthly. |
402854899 | Form 17 | 10/27/2021 | 10/27/2021 | FLOWING | 4 | WHISPER | -- | 0 | NO FLOW | 420 | 421 | No | -- | -- | Abatement system follow up test, 4 PSI whisper blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will submit sundry with bradenhead details as soon as possible. PDC will continue to monitor monthly. |
Click for Specifics | Full | 4/15/2021 | 12/21/2021 | | 1 | Down to Zero | None | 1 | No Flow | 533 | 529 | No | None | None | |
402792863 | Form 17 | 11/30/2020 | 8/26/2021 | FLOWING | 59 | WHISPER | GAS | 0 | NO FLOW | 616 | 616 | Yes | -- | -- | Post-production, 59 PSI whisper gas blew down to 0 PSI within first 5 minutes. No pressure or flow observed for the remainder of the test. PDC will submit sundry with bradenhead details as soon as possible. PDC will schedule a sampling event and submit results via form 43. |
Click for Specifics | Light | 4/30/2020 | 5/11/2020 | | 38 | | -- | 38 | | 766 | 766 | No | No | No | |
402412018 | Form 17 | 4/26/2019 | 6/3/2020 | FLOWING | 21 | DOWN TO 0 | -- | 0 | NO FLOW | 1968 | 1968 | No | -- | -- | Annual Test 2019, This form is being submitted to correct issues with the annual upload completed 12/15/2019. 21 PSI blew down to 0 PSI instantly, no pressure or flow observed for the remainder of the test. |