Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-123-45448Wilson IC
03-219HN
PDC ENERGY INC
69175
PR
8/1/2024
WATTENBERG
90750
WELD  123
NWNW 1 3N68W 6
452180
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1587 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404413512Form 1710/22/202510/29/2025PLUNGER LIFT61DOWN TO 0 WATER AND GAS0 CONTINUOUS 411410No----High Pressure Verification Test. 61 PSI water and gas blew down to PSI within first few seconds. Water observed for entire test. Operator will schedule a sampling event and submit results via form 43. Operator will continue to monitor monthly.
404326196Form 178/5/20258/21/2025PLUNGER LIFT22CONTINUOUS WATER H200 NO FLOW 307306No----Remediation follow up test. 22 PSI blew down to 0 PSI within five minutes of test. No pressure or flow observed for the remainder of the test. Operator will monitor pressure and re-test according to bradenhead policy.
404127533Form 173/5/20253/13/2025PLUNGER LIFT95CONTINUOUS WATER AND GAS0 WHISPER 304304No----Engineering Ad Hoc test. 95 PSI water and gas blew down to 0 PSI in thirty minutes. Water and gas observed for entire test. Operator will schedule a sampling event and submit results via form 43. Operator will continue to monitor monthly.
Click for SpecificsFull5/22/20246/4/2024 7Whisper (very low flow)--0Down to Zero462462NoNoNoAnnual Test.  7 PSI blew down to 0 PSI within first few seconds of test.  No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull5/25/20236/5/2023Plunger Lift3Down to Zero--0No Flow388426NoNoneNone 
Click for SpecificsFull8/16/20229/6/2022 2Down to Zero--0Down to Zero416414NoNoneNone 
Click for SpecificsLight10/27/202111/1/2021Plunger Lift21 --0 333336NoNoNoTest per NTO. Whisper on open for 20 seconds and died. No flow for remainder of test.
402546845Form 1711/25/202012/4/2020PLUNGER LIFT31CONTINUOUS GAS0 NO FLOW 579582No----Test per 2020 NTO. Gas on open for 30 seconds and died. No flow for the remainder of the test.
402255769Form 1712/4/201912/5/2019FLOWING0NO FLOW --0 NO FLOW 15781579No----Test after DOFP. Vacuum on open but died instantly.
402071529Form 176/2/20196/11/2019SHUT-IN0NO FLOW --0 NO FLOW 00No----Test prior to toe-prep/frac.