| 404226376 | Form 17 | 5/13/2025 | 6/2/2025 | PLUNGER LIFT | 60 | CONTINUOUS | WATER AND GAS | 0 | WHISPER | 424 | 424 | No | -- | -- | Remediation follow up test. 60 PSI continuous gas and water flow blew down to 0 PSI within thirty minutes, gas and water present for entire test. Operator will schedule a sampling event and submit results via form 43. Operator will monitor pressure and re-test according to bradenhead policy. |
| 403805702 | Form 17 | 5/21/2024 | 5/29/2024 | | 62 | CONTINUOUS | GAS AND LIQUID HYDROCARBON | 0 | CONTINUOUS | 468 | 468 | No | -- | -- | Annual test. 62 PSI liquid and gas flow blew down to 0 PSI in seconds. Initial continuous flow of liquid and gas, whisper of gas and trickling liquid at random for entire test. PDC will monitor pressure and re-test according to bradenhead policy.
|
| Click for Specifics | Full | 5/25/2023 | 6/5/2023 | Plunger Lift | 4 | Down to Zero | -- | 0 | No Flow | 297 | 298 | No | None | None | |
| 403203236 | Form 17 | 10/18/2022 | 10/20/2022 | PLUNGER LIFT | 295 | DOWN TO 0 | WATER AND GAS | 0 | CONTINUOUS | 383 | 392 | Yes | -- | -- | Engineering Ad Hoc test. 295 PSI water and gas blew down to 0 PSI within first few seconds of test through 1/2" needle valve. Water present for entire test, 3 gallons total fluid. PDC will schedule a sampling event and submit results via form 43. PDC will continue to monitor monthly. |
| 402857435 | Form 17 | 10/27/2021 | 10/29/2021 | PLUNGER LIFT | 9 | DOWN TO 0 | GAS | 0 | NO FLOW | 522 | 522 | No | -- | -- | Re-test after displacement and 55 day build up.
Whisper on open for 1 minute and 15 seconds and died. No flow for remainder of test. |
| 402596452 | Form 17 | 2/8/2021 | 2/10/2021 | FLOWING | 134 | CONTINUOUS | WATER H20 | 0 | CONTINUOUS | 395 | 394 | Yes | No | Yes | Test per NTO. Water at open. Drips for entire test. Made 1 gallon total. |
| 402546985 | Form 17 | 11/25/2020 | 12/4/2020 | PLUNGER LIFT | 24 | CONTINUOUS | GAS | 0 | NO FLOW | 478 | 491 | No | -- | -- | Test per 2020 NTO. Gas on open for 30 seconds and died. No flow for the remainder of the test. |
| 402255831 | Form 17 | 12/4/2019 | 12/5/2019 | SHUT-IN | 0 | NO FLOW | -- | 0 | NO FLOW | 61 | 61 | No | -- | -- | Test after DOFP. Vacuum on open but died instantly. |
| 402071236 | Form 17 | 6/2/2019 | 6/11/2019 | SHUT-IN | 0 | NO FLOW | -- | 0 | NO FLOW | 0 | 0 | Yes | -- | -- | Test prior to toe-prep/frac. |