Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-123-45442Wilson IC
03-262HN
PDC ENERGY INC
69175
PR
8/1/2024
WATTENBERG
90750
WELD  123
NWNW 1 3N68W 6
452180
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1569 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404226376Form 175/13/20256/2/2025PLUNGER LIFT60CONTINUOUS WATER AND GAS0 WHISPER 424424No----Remediation follow up test. 60 PSI continuous gas and water flow blew down to 0 PSI within thirty minutes, gas and water present for entire test. Operator will schedule a sampling event and submit results via form 43. Operator will monitor pressure and re-test according to bradenhead policy.
403805702Form 175/21/20245/29/2024 62CONTINUOUS GAS AND LIQUID HYDROCARBON0 CONTINUOUS 468468No----Annual test. 62 PSI liquid and gas flow blew down to 0 PSI in seconds. Initial continuous flow of liquid and gas, whisper of gas and trickling liquid at random for entire test. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull5/25/20236/5/2023Plunger Lift4Down to Zero--0No Flow297298NoNoneNone 
403203236Form 1710/18/202210/20/2022PLUNGER LIFT295DOWN TO 0 WATER AND GAS0 CONTINUOUS 383392Yes----Engineering Ad Hoc test. 295 PSI water and gas blew down to 0 PSI within first few seconds of test through 1/2" needle valve. Water present for entire test, 3 gallons total fluid. PDC will schedule a sampling event and submit results via form 43. PDC will continue to monitor monthly.
402857435Form 1710/27/202110/29/2021PLUNGER LIFT9DOWN TO 0 GAS0 NO FLOW 522522No----Re-test after displacement and 55 day build up. Whisper on open for 1 minute and 15 seconds and died. No flow for remainder of test.
402596452Form 172/8/20212/10/2021FLOWING134CONTINUOUS WATER H200 CONTINUOUS 395394YesNoYesTest per NTO. Water at open. Drips for entire test. Made 1 gallon total.
402546985Form 1711/25/202012/4/2020PLUNGER LIFT24CONTINUOUS GAS0 NO FLOW 478491No----Test per 2020 NTO. Gas on open for 30 seconds and died. No flow for the remainder of the test.
402255831Form 1712/4/201912/5/2019SHUT-IN0NO FLOW --0 NO FLOW 6161No----Test after DOFP. Vacuum on open but died instantly.
402071236Form 176/2/20196/11/2019SHUT-IN0NO FLOW --0 NO FLOW 00Yes----Test prior to toe-prep/frac.