Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-123-45440Wilson IC
03-222HNX
PDC ENERGY INC
69175
PR
8/1/2024
WATTENBERG
90750
WELD  123
NWNW 1 3N68W 6
452180
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1585 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404326206Form 178/5/20258/21/2025PLUNGER LIFT55CONTINUOUS WATER AND GAS0 NO FLOW 315325No----Remediation follow up test. 55 PSI whisper blew down to 0 PSI within five minutes of test. No pressure or flow observed for the remainder of the test. Operator will monitor pressure and re-test according to bradenhead policy.
404111813Form 172/19/20252/28/2025PLUNGER LIFT103CONTINUOUS WATER AND GAS1 CONTINUOUS 353346No----Engineering Ad Hoc test. 103 PSI water and gas blew down to 1 PSI in thirty minutes. Operator will schedule a sampling event and submit results via form 43. Operator will continue to monitor monthly.
403815755Form 176/5/20246/6/2024INJECTION125CONTINUOUS WATER AND GAS0 WHISPER 360358No----Annual test. 125 PSI gas and fluid blew down to 0 PSI in 5 minutes. Fluid present for remainder of test, ~1.5 gallons total water. PDC will schedule a sampling event and submit results via form 43. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull5/22/20246/4/2024 15Whisper (very low flow)--0Down to Zero458458NoNoNoAnnual Test.  15 PSI blew down to 0 PSI within first few seconds of test.  No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull5/25/20236/5/2023Plunger Lift5Down to Zero--0No Flow381375NoNoneNone 
Click for SpecificsFull8/16/20229/6/2022 13Down to Zero--0Down to Zero326325NoNoneNone 
402808126Form 179/2/20219/11/2021PLUNGER LIFT19DOWN TO 0 GAS0 NO FLOW 375373No----Test per NTO. Gas on open for 35 seconds and died. No flow for remainder of test.
402546854Form 1711/25/202012/4/2020PLUNGER LIFT4WHISPER GAS0 NO FLOW 552551No----Test per 2020 NTO. Whisper on open for 2 seconds and died. No flow for the remainder of the test.
402255796Form 1712/4/201912/5/2019FLOWING0NO FLOW --0 NO FLOW 15761558No----Test after DOFP. Vacuum on open, died instantly.
402071247Form 176/2/20196/11/2019SHUT-IN0NO FLOW --0 NO FLOW 00No----Test prior to toe-prep/frac