Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-123-45439Wilson IC
03-179HNX
PDC ENERGY INC
69175
PR
8/1/2024
WATTENBERG
90750
WELD  123
NWNW 1 3N68W 6
452180
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1574 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404226349Form 175/13/20256/2/2025PLUNGER LIFT113CONTINUOUS WATER AND GAS0 CONTINUOUS 346336No----Remediation follow up test. 113 PSI continuous gas and water flow blew down to 0 PSI within thirty minutes, gas and water present for entire test. Operator will schedule a sampling event and submit results via form 43. Operator will monitor pressure and re-test according to bradenhead policy.
403805688Form 175/22/20245/28/2024 53CONTINUOUS GAS AND LIQUID HYDROCARBON0 CONTINUOUS 463463No----Annual test. 53 PSI liquid and gas flow blew down to 0 PSI in seconds. Initial continuous flow of liquid and gas, whisper of gas and surges of trickling liquid at random for entire test. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull6/5/20236/12/2023 8Down to Zero--0No Flow271269NoNoNoAnnual Test. 8 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
403079721Form 176/13/20226/15/2022FLOWING88DOWN TO 0 GAS0 NO FLOW 286287No----Test after pressure discovery. Gaseous on open for 5 seconds and died. Unable to sample due to lack of volume. No flow for remainder of test.
402857446Form 1710/27/202110/29/2021PLUNGER LIFT2WHISPER GAS0 NO FLOW 338337No----Re-test after displacement and 24 day build up. Whisper on open for 35 seconds and died. No flow for remainder of test.
402838153Form 179/30/202110/12/2021FLOWING210CONTINUOUS WATER H200 CONTINUOUS 350345YesNoYesTest per NTO after pressure. Water at open. Water continuous for entire test. Made 2.5 gallons total.
402808093Form 179/2/20219/11/2021PLUNGER LIFT23WHISPER GAS0 NO FLOW 355357No----Test per NTO. Whisper on open for 5 seconds and died. No flow for remainder of test.
402546712Form 1711/25/202012/4/2020PLUNGER LIFT9WHISPER GAS0 NO FLOW 558562No----Test per 2020 NTO. Whisper on open for 20 seconds and died. No flow for the remainder of the test.
402260814Form 1712/4/201912/11/2019FLOWING1DOWN TO 0 --0 NO FLOW 13721422No----Test after DOFP. Blew dead in less than 5 seconds. BH dead.
402071521Form 176/2/20196/11/2019SHUT-IN0NO FLOW --0 NO FLOW 00No----Test prior to toe-prep/frac.