Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-123-45437Wilson IC
03-379HN
PDC ENERGY INC
69175
PR
8/1/2024
WATTENBERG
90750
WELD  123
NWNW 1 3N68W 6
452180
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1587 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404413753Form 1710/22/202510/29/2025PLUNGER LIFT10DOWN TO 0 GAS0 NO FLOW 512511No----Remediation follow up test. 10 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. Operator will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull5/21/20256/5/2025 8Continuous--0No Flow560558NoNoNoAnnual Test.  8 PSI blew down to 0 PSI within first few seconds of test.  No pressure or flow observed for the remainder of the test. Operator will monitor pressure and re-test according to bradenhead policy.
403985605Form 1710/30/202411/6/2024 0NO FLOW NONE0 NO FLOW 848848No----Remediation follow up test. 0 PSI, no pressure or flow observed. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull5/17/20246/18/2024 15Whisper (very low flow)--0Down to Zero500500NoNoNoAnnual Test.  15 PSI blew down to 0 PSI within first few seconds of test.  No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull6/5/20236/12/2023 10Down to Zero--0No Flow884884NoNoNoAnnual Test. 10 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
403079772Form 176/13/20226/15/2022PLUNGER LIFT64DOWN TO 0 GAS0 NO FLOW 678682No----Test after pressure discovery. Gaseous on open for 7 seconds and died. Unable to sample due to lack of volume. No flow for remainder of test.
402807174Form 179/2/20219/10/2021PLUNGER LIFT7WHISPER GAS0 NO FLOW 629629No----Test after displacement and 89 day build up. Whisper on open for 30 seconds and died.
402705032Form 175/26/20216/1/2021FLOWING253CONTINUOUS WATER H200 CONTINUOUS 742742YesNoYesTest per NTO. Water at open. Water continued for entire test. Made 2 gallons total.
402547029Form 1711/25/202012/4/2020SHUT-IN12CONTINUOUS GAS0 NO FLOW 691691No----Test per 2020 NTO. Gas on open for 5 seconds and died. No flow for the remainder of the test.
402260849Form 1712/4/201912/11/2019FLOWING0NO FLOW --0 NO FLOW 18171817No----Test after DOFP. BH dead.
402071180Form 176/2/20196/11/2019SHUT-IN0NO FLOW --0 NO FLOW 00No----Test prior to toe-prep/frac.