WELL05-123-45430Wilson IC
03-142HN
PDC ENERGY INC
69175
PR
8/1/2024
WATTENBERG
90750
WELD  123
NWNW 1 3N68W 6
452180
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1569 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404226328Form 175/13/20256/2/2025PLUNGER LIFT83CONTINUOUS WATER AND GAS0 WHISPER 362351No----Remediation follow up test. 83 PSI continuous gas and water flow blew down to 0 PSI within thirty minutes, gas and water present for entire test. Operator will schedule a sampling event and submit results via form 43. Operator will monitor pressure and re-test according to bradenhead policy.
403805642Form 175/21/20245/28/2024 54CONTINUOUS GAS AND LIQUID HYDROCARBON0 CONTINUOUS 465465No----Annual test. 54 PSI liquid and gas flow blew down to 0 PSI in 30 seconds. Initial continuous flow of liquid and gas, whisper of gas and surges of trickling liquid at random for entire test. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull6/5/20236/12/2023 10Down to Zero--0No Flow305302NoNoNoAnnual Test. 10 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
403203312Form 1710/18/202210/20/2022PLUNGER LIFT91DOWN TO 0 GAS0 NO FLOW 310311Yes----Engineering Ad Hoc test. 91 PSI gas flow blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will schedule a sampling event and submit results via form 43. PDC will continue to monitor monthly.
403079703Form 176/10/20226/15/2022PLUNGER LIFT83DOWN TO 0 GAS0 NO FLOW 320316No----Test after pressure discovery. Gaseous on open for 10 seconds and died. Unable to collect gas sample due to lac of volume. No flow for remainder of test.
402725167Form 176/21/20216/21/2021PLUNGER LIFT7DOWN TO 0 GAS0 NO FLOW 431435No----Test after cat heater mitigation and 30 day build up. Whisper on open for 2 minutes and died. No flow for remainder of test.
402454267Form 177/27/20207/28/2020FLOWING119GAS --0 WHISPER 760757YesYesNoTest after rig work and 72 hour build up. Gas at open down to a whisper at 25 minute mark. Contunous flow throught test, but decreasing over time.
402260822Form 1712/4/201912/11/2019FLOWING537CONTINUOUS --8 CONTINUOUS 14721496YesYes--Test after DOFP. blew down thru 2"/ 10/64th choke to frac tank. Continuous gas flow entire test.
402071575Form 176/2/20196/11/2019SHUT-IN0NO FLOW --0 NO FLOW 00No----Test prior to toe-prep/frac