Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-123-45429Wilson IC
03-382HN
PDC ENERGY INC
69175
PR
8/1/2024
WATTENBERG
90750
WELD  123
NWNW 1 3N68W 6
452180
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1590 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404226704Form 175/13/20256/3/2025SHUT-IN5CONTINUOUS GAS0 NO FLOW 678635No----Remediation follow up test. 5 PSI whisper blew down to 0 PSI within five minutes of test. No pressure or flow observed for the remainder of the test. Operator will monitor pressure and re-test according to bradenhead policy.
403809294Form 175/23/20245/31/2024SHUT-IN29CONTINUOUS GAS AND LIQUID HYDROCARBON0 WHISPER 519519No----Annual test. 29 PSI blew down to PSI in 2 minutes. Solid stream of liquid gas on open, fluid trickle and whisper for entire test. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull6/5/20236/12/2023 8Down to Zero--0No Flow706708NoNoNoAnnual Test. 8 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
403203368Form 1710/18/202210/20/2022GAS LIFT179CONTINUOUS WATER AND GAS0 CONTINUOUS 709709Yes----Engineering Ad Hoc test. 179 PSI water and gas flow blew down to 0 PSI within first few seconds of test through 1/2" needle valve. Water present for entire test, 2 gallon total fluid. PDC will schedule a sampling event and submit results via form 43. PDC will continue to monitor monthly.
Click for SpecificsFull8/16/20229/6/2022 21Down to Zero--0Down to Zero621314NoNoneNone 
402808128Form 179/8/20219/11/2021PLUNGER LIFT1WHISPER GAS0 NO FLOW 946946No----Test per NTO. Whisper on open for 20 seconds and died. No flow for remainder of test.
402547033Form 1711/25/202012/4/2020SHUT-IN--NO FLOW NONE0 NO FLOW 12281209No----Test per 2020 NTO. Slight vacuum on open.
402260844Form 1712/4/201912/11/2019FLOWING0NO FLOW --0 NO FLOW 19161917No----Test after DOFP. BH dead.
402071187Form 176/2/20196/11/2019SHUT-IN0NO FLOW --0 NO FLOW 00No----Test prior to toe-prep/frac