| 404229543 | Form 17 | 5/21/2025 | 6/4/2025 | PLUNGER LIFT | 3 | CONTINUOUS | GAS | 0 | NO FLOW | 375 | 376 | No | -- | -- | Remediation follow up test. 3 PSI gas blew down to 0 PSI within five minutes of test. No pressure or flow observed for the remainder of the test. Operator will monitor pressure and re-test according to bradenhead policy. |
| Click for Specifics | Full | 5/20/2024 | 5/30/2024 | | 15 | Whisper (very low flow) | -- | 0 | Down to Zero | 475 | 475 | No | No | No | Annual Test. 15 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy. |
| 403479824 | Form 17 | 7/27/2023 | 7/28/2023 | INJECTION | 88 | CONTINUOUS | GAS | 0 | NO FLOW | 306 | 307 | Yes | -- | -- | High Pressure Verification test. 88 PSI gas flow blew down to 0 PSI in 5 minutes. No flow or pressure for remainder of test. PDC will schedule a sampling event and submit results via form 43. PDC will monitor pressure and re-test according to bradenhead policy. |
| Click for Specifics | Full | 6/5/2023 | 6/12/2023 | | 37 | Down to Zero | -- | 0 | No Flow | 308 | 310 | No | No | No | Annual Test. 37 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy. |
| Click for Specifics | Full | 8/16/2022 | 9/6/2022 | | 14 | Down to Zero | -- | 0 | Down to Zero | 334 | 335 | No | None | None | |
| 402808102 | Form 17 | 9/2/2021 | 9/11/2021 | PLUNGER LIFT | 19 | DOWN TO 0 | GAS | 0 | NO FLOW | 445 | 444 | No | -- | -- | Test per NTO. Gas on open for 40 seconds and died. No flow for remainder of test. |
| 402381999 | Form 17 | 4/20/2020 | 4/27/2020 | FLOWING | 15 | GAS | -- | 0 | NO FLOW | 1078 | 1073 | No | -- | -- | Test after displacment and 26 day build up. Gas for 15 seconds then dead. |
| 402304816 | Form 17 | 1/26/2020 | 2/5/2020 | FLOWING | 142 | WATER H20 | -- | 0 | WATER H20 | 1296 | 1296 | No | -- | -- | Test after 5 week blowdown and 1 week buildup. Down to trickle after 5 seconds and down to drip at 5 minute mark. made ~2 quarts total. |
| 402260829 | Form 17 | 12/4/2019 | 12/11/2019 | FLOWING | 122 | WATER H20 | -- | 0 | NO FLOW | 1604 | 1609 | No | -- | -- | Test after DOFP. Produced ~750mL of water and died at 9 minute mark. Not an adequate amount of water to sample. |
| 402071560 | Form 17 | 6/2/2019 | 6/11/2019 | SHUT-IN | 0 | NO FLOW | -- | 0 | NO FLOW | 0 | 0 | No | -- | -- | Test prior to toe-prep/frac. |