Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-123-45428Wilson IC
03-142HC
PDC ENERGY INC
69175
PR
8/1/2024
WATTENBERG
90750
WELD  123
NWNW 1 3N68W 6
452180
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1569 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404229543Form 175/21/20256/4/2025PLUNGER LIFT3CONTINUOUS GAS0 NO FLOW 375376No----Remediation follow up test. 3 PSI gas blew down to 0 PSI within five minutes of test. No pressure or flow observed for the remainder of the test. Operator will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull5/20/20245/30/2024 15Whisper (very low flow)--0Down to Zero475475NoNoNoAnnual Test.  15 PSI blew down to 0 PSI within first few seconds of test.  No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
403479824Form 177/27/20237/28/2023INJECTION88CONTINUOUS GAS0 NO FLOW 306307Yes----High Pressure Verification test. 88 PSI gas flow blew down to 0 PSI in 5 minutes. No flow or pressure for remainder of test. PDC will schedule a sampling event and submit results via form 43. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull6/5/20236/12/2023 37Down to Zero--0No Flow308310NoNoNoAnnual Test. 37 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull8/16/20229/6/2022 14Down to Zero--0Down to Zero334335NoNoneNone 
402808102Form 179/2/20219/11/2021PLUNGER LIFT19DOWN TO 0 GAS0 NO FLOW 445444No----Test per NTO. Gas on open for 40 seconds and died. No flow for remainder of test.
402381999Form 174/20/20204/27/2020FLOWING15GAS --0 NO FLOW 10781073No----Test after displacment and 26 day build up. Gas for 15 seconds then dead.
402304816Form 171/26/20202/5/2020FLOWING142WATER H20 --0 WATER H20 12961296No----Test after 5 week blowdown and 1 week buildup. Down to trickle after 5 seconds and down to drip at 5 minute mark. made ~2 quarts total.
402260829Form 1712/4/201912/11/2019FLOWING122WATER H20 --0 NO FLOW 16041609No----Test after DOFP. Produced ~750mL of water and died at 9 minute mark. Not an adequate amount of water to sample.
402071560Form 176/2/20196/11/2019SHUT-IN0NO FLOW --0 NO FLOW 00No----Test prior to toe-prep/frac.