| 404226322 | Form 17 | 5/13/2025 | 6/2/2025 | SHUT-IN | 45 | CONTINUOUS | WATER AND GAS | 0 | WHISPER | 426 | 428 | No | -- | -- | Remediation follow up test. 45 PSI continuous gas and water flow blew down to 0 PSI within thirty minutes, gas and water observed throughout entire test. Operator will schedule a sampling event and submit results via form 43. Operator will monitor pressure and re-test according to bradenhead policy. |
| 403805608 | Form 17 | 5/21/2024 | 5/28/2024 | | 51 | CONTINUOUS | GAS AND LIQUID HYDROCARBON | 0 | CONTINUOUS | 495 | 495 | No | -- | -- | Annual Test. 51 PSI blew down to 0 PSI in 20 seconds. Initial continuous flow of liquid and gas, whisper of as and surges of trickling liquid at random throughout entire test. Total liquid collected after 30 minute test ~>8oz of fluid. PDC will monitor pressure and re-test according to bradenhead policy. |
| Click for Specifics | Full | 6/5/2023 | 6/12/2023 | | 42 | Down to Zero | -- | 0 | No Flow | 303 | 299 | No | No | No | Annual Test. 42 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy. |
| 403203347 | Form 17 | 10/18/2022 | 10/20/2022 | PLUNGER LIFT | 296 | DOWN TO 0 | GAS AND LIQUID HYDROCARBON | 0 | CONTINUOUS | 307 | 307 | Yes | -- | -- | Engineering Ad Hoc test. 296 PSI gas and liquid flow blew down to 0 PSI within first few seconds of test through 1/2" needle valve. Water continued for duration of test, 2 gallon total fluid. PDC will schedule a sampling event and submit results via form 43. PDC will continue to monitor monthly. |
| 402857469 | Form 17 | 10/27/2021 | 10/29/2021 | PLUNGER LIFT | 7 | DOWN TO 0 | GAS | 0 | NO FLOW | 338 | 337 | No | -- | -- | Re-test after displacement and 24 day build up.
Whisper on open for 25 seconds and died. No flow for remainder of test. |
| 402838216 | Form 17 | 9/30/2021 | 10/12/2021 | FLOWING | 155 | DOWN TO 0 | WATER AND GAS | 0 | CONTINUOUS | 353 | 354 | Yes | No | Yes | Test per NTO after pressure. Gas for 2 sec then water. Water continuous for remainder of test. Made 2 gallons total. |
| 402805391 | Form 17 | 9/2/2021 | 9/8/2021 | PLUNGER LIFT | 26 | WHISPER | GAS | 0 | NO FLOW | 368 | 362 | No | -- | -- | Test after displacement and 42 day builup.
Gas on open for 40 seconds and died. No flow for remainder of test. |
| 402704932 | Form 17 | 5/25/2021 | 6/1/2021 | FLOWING | 244 | CONTINUOUS | WATER H20 | 0 | CONTINUOUS | 407 | 405 | Yes | No | Yes | Test per NTO. Water at open. Water continued for entire test. Made 2 gallons total. |
| Click for Specifics | Light | 12/4/2020 | 12/14/2020 | Flowing | 0 | | -- | 0 | No Flow | 530 | 536 | No | No | No | Test per NTO. Whisper for 2 seconds at open then dead. |
| 402260843 | Form 17 | 12/4/2019 | 12/11/2019 | FLOWING | 0 | NO FLOW | -- | 0 | NO FLOW | 1150 | 1144 | No | -- | -- | Test after DOFP. whisper on open, blew dead in less than 1 minute. BH dead. |
| 402071490 | Form 17 | 6/2/2019 | 6/11/2019 | SHUT-IN | 0 | NO FLOW | -- | 0 | NO FLOW | 0 | 0 | No | -- | -- | Test prior to toe-prep/frac. |