Click for Specifics | Full | 7/17/2024 | 7/29/2024 | | 17 | Down to Zero | -- | 0 | No Flow | 480 | 479 | No | No | No | Annual Test. 17 PSI, with no pressure or flow observed for the entire 30-minute test. PDC will monitor pressure and re-test according to bradenhead policy. |
Click for Specifics | Full | 10/9/2023 | 10/16/2023 | Plunger Lift | 1 | Down to Zero | -- | 0 | Down to Zero | 503 | 498 | No | No | No | Annual Test. 1 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy. |
403277888 | Form 17 | 12/28/2022 | 1/3/2023 | GAS LIFT | 0 | DOWN TO 0 | GAS | 0 | NO FLOW | 353 | 353 | No | -- | -- | Abatement system follow up test. 0 PSI, no pressure or flow observed. PDC will submit sundry with bradenhead details if needed as soon as possible. PDC will continue to monitor monthly. |
403051711 | Form 17 | 5/12/2022 | 5/17/2022 | FLOWING | 113 | DOWN TO 0 | WATER H20 | 0 | CONTINUOUS | 445 | 441 | Yes | -- | Yes | Failed retest. Water on open. Attempted 1000mL water sample, only collected 750mL at end of test. |
402870060 | Form 17 | 11/3/2021 | 11/12/2021 | FLOWING | 165 | DOWN TO 0 | WATER AND GAS | 0 | NO FLOW | 407 | 409 | No | -- | -- | Test per NTO. Gas for 1 second. Then water for 5 seconds then dead. Not enough water for sample. |
Click for Specifics | Light | 12/8/2020 | 12/21/2020 | Flowing | 11 | | -- | 0 | No Flow | 588 | 588 | No | No | No | Test per NTO. Gas for 5 seconds at open then dead. |
402239631 | Form 17 | 11/8/2019 | 11/14/2019 | FLOWING | 9 | DOWN TO 0 | -- | 0 | NO FLOW | 1079 | 1079 | No | -- | -- | Test after DOFP. Delay due to continuous surface operations. Blew dead < 5 secs. BH dead. |
401989483 | Form 17 | 3/28/2019 | 3/29/2019 | SHUT-IN | 115 | NO FLOW | -- | 0 | NO FLOW | 0 | 0 | Yes | Yes | -- | Test before frac. Died in 5 seconds. Build up for sample. Died after sample collection. No production sample taken, well has not been completed yet. |
401668448 | Form 17 | 6/1/2018 | 6/8/2018 | SHUT-IN | 145 | WHISPER | -- | 0 | NO FLOW | 300 | 300 | No | -- | -- | Second test, 6 months after rig release. Blew down to whisper in less than 5 seconds. Well not completed. |
401458663 | Form 17 | 11/13/2017 | 11/15/2017 | SHUT-IN | 65 | DOWN TO 0 | -- | 0 | NO FLOW | 1180 | 1180 | No | -- | -- | |