404008265 | Form 17 | 11/25/2024 | 11/26/2024 | FLOWING | 18 | CONTINUOUS | WATER AND GAS | 0 | DOWN TO 0 | 368 | 377 | No | -- | -- | Remediation follow up test. 18 PSI continuous gas and water flow blew down to 0 PSI within thirty minutes. PDC will schedule a sampling event and submit results via form 43. PDC will monitor pressure and re-test according to bradenhead policy. |
403799277 | Form 17 | 5/14/2024 | 5/21/2024 | SHUT-IN | 103 | CONTINUOUS | WATER AND GAS | 0 | WHISPER | 0 | 0 | No | -- | -- | Annual test. 103 PSI cloudy water and gas flow blew down to 0 PSI in seconds, whisper gas and fluid trickle for entire test. PDC will monitor pressure and re-test according to bradenhead policy. |
403280479 | Form 17 | 1/4/2023 | 1/5/2023 | SHUT-IN | 10 | DOWN TO 0 | GAS | 0 | NO FLOW | 367 | 367 | No | -- | -- | Abatement system follow up test. 10 PSI gas flow blew down to 0 PSI within first few seconds of test through 1/2" needle valve. Water started at 4 minutes and stopped at 21 minutes, 1 qt total fluid. PDC will submit sundry with bradenhead details as soon as possible. PDC will continue to monitor monthly. |
403079647 | Form 17 | 6/8/2022 | 6/15/2022 | PLUNGER LIFT | 140 | DOWN TO 0 | WATER H20 | 0 | CONTINUOUS | 318 | 318 | Yes | -- | Yes | Test after pressure discovery. Water on open, produced about 200 mL and died to trickle/drip. Collected 1000mL water sample. Produced about 3000mL total. |
Click for Specifics | Light | 11/3/2021 | 11/15/2021 | Shut-In | 0 | | -- | 0 | | 273 | 273 | No | No | No | Test per NTO. Dead at open. |
402548545 | Form 17 | 12/1/2020 | 12/8/2020 | FLOWING | 24 | CONTINUOUS | WATER H20 | 0 | CONTINUOUS | 432 | 423 | Yes | No | Yes | Test per NTO. Water at open, drips for entire test. Made 1 gallon total. |
402239525 | Form 17 | 11/7/2019 | 11/14/2019 | FLOWING | 9 | DOWN TO 0 | -- | 0 | NO FLOW | 901 | 900 | No | -- | -- | Test after DOFP. Delay due to continuous surface operations. Produced 3 cups of water on open then died < 10 secs. BH dead. |
401989646 | Form 17 | 3/28/2019 | 3/29/2019 | SHUT-IN | 25 | NO FLOW | -- | 0 | NO FLOW | 0 | 0 | No | -- | -- | Test before frac. Died in less than 3 seconds. |
401668405 | Form 17 | 6/1/2018 | 6/8/2018 | SHUT-IN | 10 | NO FLOW | -- | 0 | NO FLOW | 0 | 0 | No | -- | -- | Second test, six months after rig release. Blew down in less than one second. Well not completed. |
401458685 | Form 17 | 11/13/2017 | 11/14/2017 | SHUT-IN | 0 | NO FLOW | -- | 0 | NO FLOW | 0 | 0 | No | -- | -- | |