WELL05-123-44863Geib
26U-304
PDC ENERGY INC
69175
PR
3/1/2022
WATTENBERG
90750
WELD  123
NENE 26 5N65W 6
450654
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1631 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404292508Form 177/10/20257/24/2025PLUNGER LIFT126DOWN TO 0 GAS45 WHISPER 607627No----Remediation follow up test. 126 PSI gas flow blew down to 45 PSI within thirty minutes, gas observed throughout entire test. Operator will schedule a sampling event and submit results via form 43. Operator will monitor pressure and re-test according to bradenhead policy.
403867974Form 177/23/20247/26/2024PLUNGER LIFT79DOWN TO 0 GAS0 NO FLOW 385387No----Annual Test. 79 PSI gas flow blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull9/20/20239/25/2023Plunger Lift0Down to Zero--0Down to Zero478474NoNoNoAnnual Test. 0 PSI, with no pressure or flow observed for the entire 30-minute test. PDC will monitor pressure and re-test according to bradenhead policy.
403084641Form 176/20/20226/21/2022PLUNGER LIFT112DOWN TO 0 GAS0 NO FLOW 437437Yes----Annual Test, 112 PSI gas flow blew down to 0 PSI within first minute of test. No pressure or flow observed for the remainder of the test. PDC collected a sample 6/8/2022 and will submit results via form 43 as soon as possible. PDC will continue to monitor monthly.
402939943Form 171/27/20221/28/2022SHUT-IN100CONTINUOUS WATER H200 NO FLOW 731731Yes----Ad Hoc Engineering test, 100 PSI slight water blew down to 0 PSI within first 5 minutes of test. No pressure or flow observed for the remainder of the test. PDC will schedule a sampling event and submit results via form 43 as well as a remediation plan via sundry as soon as possible. PDC will continue to monitor monthly.
402719995Form 175/6/20216/16/2021PLUNGER LIFT6DOWN TO 0 WATER AND VAPOR0  575575No----Abatement system follow up test, 6 PSI whisper blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will submit sundry with bradenhead details as soon as possible.
402541678Form 1711/13/202011/30/2020 74WHISPER GAS0 NO FLOW 646643No----6 month follow-up test post abatement system install. PDC will continue to monitor pressure and report any increase in pressure to COGCC.
402456109Form 173/12/20207/29/2020FLOWING159GAS --0 NO FLOW 758758No----Abatement System Follow up test, 159 PSI blew down to 0 PSI within first minute of test. no pressure or flow observed for remainder of test. PDC will attempt to collect a sample and submit results. PDC will follow up with a sundry and re-test in 6 months.
402034416Form 174/26/20195/7/2019FLOWING143DOWN TO 0 --0 NO FLOW 17601760No----143 PSI blew down to 0 PSI instantly, no flow or pressure for the remainder of bradenhead test. PDC will follow up with a sundry proposing a remediation plan for bradenhead pressure.
401760501Form 177/29/20189/12/2018SHUT-IN105DOWN TO 0 --0 NO FLOW 00No----Post TD test, 105 PSI blew down to 0 PSI within seconds of test, no flow or pressure for remainder of test.