Surface Casing Depth: 1631 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404304728Form 177/15/20258/4/2025PLUNGER LIFT60DOWN TO 0 WATER AND GAS0 CONTINUOUS 630633No----Remediation follow up test. 60 PSI gas and water, blew down to 0 within first few seconds, water continued for entire test. Operator will schedule a sampling event and submit results via form 43. Operator will monitor pressure and re-test according to bradenhead policy.
403867462Form 177/23/20247/26/2024PLUNGER LIFT68DOWN TO 0 WATER AND GAS0 CONTINUOUS 434436No----Annual test. 68 PSI water and gas flow blew down to 0 PSI in seconds, water continued to drip for entire test. PDC will monitor pressure and re-test according to bradenhead policy.
403536893Form 179/20/20239/21/2023PLUNGER LIFT54CONTINUOUS WATER AND GAS0 CONTINUOUS 533532No----Annual test. 54 PSI water and gas flow blew down to 0 PSI in 3.5 minutes. No flow or pressure until 18 minute mark when light trickle of fluid started again. ~2.5 gallons total fluid. PDC will monitor pressure and re-test according to bradenhead policy.
403084635Form 176/20/20226/21/2022PLUNGER LIFT56CONTINUOUS WATER AND GAS0 CONTINUOUS 417417Yes----Annual Test, 56 PSI water and gas flow blew down to 0 PSI within first minute of test. No pressure observed for the remainder of the test, water present for the duration of the test. PDC collected a sample 6/8/2022 and will submit results via form 43 as soon as possible. PDC will continue to monitor monthly.
402719997Form 175/6/20216/16/2021PLUNGER LIFT7WHISPER WATER AND VAPOR0  524524No----Abatement system follow up test, 7 PSI whisper blew down to 0 PSI within first five minutes. No pressure or flow observed for the remainder of the test. PDC will submit sundry with bradenhead details as soon as possible.
402545043Form 1711/13/202012/2/2020FLOWING57WHISPER GAS0 NO FLOW 587587No----Abatement System Follow up Test, 57 PSI slight gas blew down to 0 PSI within first 5 minute of test. No pressure or flow observed for the remainder of the test.
402456097Form 173/12/20207/29/2020FLOWING133GAS --0 NO FLOW 741741No----Abatement System Follow up test, 133 PSI blew down to 0 PSI within first minute of test. no pressure or flow observed for remainder of test. PDC will attempt to collect a sample and submit results. PDC will follow up with a sundry and re-test in 6 months.
402035966Form 174/25/20195/8/2019FLOWING165CONTINUOUS --0 NO FLOW 20072007No----165 PSI blew down to 0 PSI within first 5 minutes, no flow or pressure for the remainder of bradenhead test. PDC will follow up with a sundry proposing a remediation plan for bradenhead pressure.
401760526Form 177/29/20189/12/2018SHUT-IN200DOWN TO 0 --0 NO FLOW 00No----Post TD test 200 PSI blew down to 0 within seconds, no flow or pressure for duration of test