404082549 | Form 17 | 2/4/2025 | 2/5/2025 | | 17 | CONTINUOUS | WATER AND GAS | 1 | WHISPER | 363 | 328 | No | -- | -- | ABATEMENT- Surface Casing produced Water. Water insufficient for sampling. |
403895794 | Form 17 | 8/9/2024 | 8/21/2024 | | 56 | CONTINUOUS | WATER H20 | 1 | WHISPER | 328 | 362 | No | -- | -- | Surface Casing produced Water. |
403784619 | Form 17 | 5/8/2024 | 5/9/2024 | | 18 | CONTINUOUS | WATER H20 | 1 | WHISPER | 317 | 347 | No | -- | -- | Surface Casing produced Water. Water insufficient for sampling. |
403732861 | Form 17 | 3/22/2024 | 3/27/2024 | | 77 | CONTINUOUS | GAS AND LIQUID HYDROCARBON | 1 | WHISPER | 351 | 361 | No | -- | -- | Surface Casing produced Liquid Hydrocarbon. |
Click for Specifics | Full | 3/12/2024 | 6/18/2024 | | 11 | Continuous | Liquid Hydrocarbon | -- | Whisper | 494 | 498 | No | N | N | Surface Casing produced Liquid Hydrocarbon. Liquid Hydrocarbon insufficient for sampling. |
Click for Specifics | Full | 2/15/2023 | 3/8/2023 | Plunger Lift | 0 | No Flow | None | -- | No Flow | 282 | 282 | No | N | N | Surface Casing produced no liquid. |
Click for Specifics | Full | 3/10/2022 | 4/18/2022 | Plunger Lift | 1 | Whisper | None | -- | No Flow | 409 | 390 | No | N | N | Surface Casing produced no liquid. |
Click for Specifics | Full | 3/26/2021 | 4/19/2021 | Plunger Lift | 0 | No Flow | None | -- | No Flow | 487 | 487 | No | No | No | Surface Casing produced no liquid. |
Click for Specifics | Full | 2/4/2020 | 6/8/2020 | | 7 | Continuous Flow | | 0 | Down To Zero | 425 | 418 | No | No | No | Surface casing produced no liquid. |
Click for Specifics | Full | 10/15/2019 | 12/10/2019 | | 16 | Gas | | 0 | Down To Zero | 739 | 753 | No | No | No | Surface casing produced no liquid. |
401658787 | Form 17 | 5/24/2018 | 5/31/2018 | PLUNGER LIFT | 33 | GAS | -- | 1 | WHISPER | 2267 | 2267 | No | -- | -- | Surface casing produced no fluids. Blew down surface casing an extra 30 minutes ended with a whisper. Surface casing shut in for 15 minutes ended with 5 PSI. |
401658734 | Form 17 | 5/24/2018 | 5/31/2018 | PLUNGER LIFT | 33 | GAS | -- | 1 | WHISPER | 2267 | 2267 | No | -- | -- | Surface casing produced no fluids. Blew down surface casing an extra 30 minutes ended with a whisper. Surface casing shut in for 15 minutes ended with 5 PSI. |
401456802 | Form 17 | 10/30/2017 | 11/13/2017 | | 220 | GAS | -- | 1 | WHISPER | 43 | 43 | No | -- | -- | SURFACE CASING PRODUCED NO FLUIDS. BLEW DOWN SURFACE CASING AN EXTRA 30 MIN ENDED WITH A WHISPER OF GAS. SHUT IN SURFACE CASING FOR 15 MIN ENDED WITH 11 PSI. POST DRILL FORM 17. |