Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-123-44093Bunting
26Q-304
PDC ENERGY INC
69175
PR
4/3/2019
WATTENBERG
90750
WELD  123
SWSE 26 5N65W 6
448963
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1627 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
403879702Form 178/1/20248/7/2024PLUNGER LIFT28CONTINUOUS WATER AND GAS11 CONTINUOUS 425433No----Annual test. 28 PSI continuous water and gas flow blew down to 11 PSI in 30 minutes, ~4 gallons of fluid total. PDC will monitor pressure and re-test according to bradenhead policy.
403539678Form 179/19/20239/25/2023PLUNGER LIFT14CONTINUOUS WATER AND GAS0 CONTINUOUS 451447Yes----Annual Test. 14 PSI water and gas flow blew down to 0 PSI within first minute of test. Water dripped for entire test. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull1/24/20222/21/2022 13Down to Zero--0Down to Zero351352NoNoNo 
Click for SpecificsFull4/12/202112/21/2021 5Down to ZeroNone1No Flow480576NoNoneNone 
402447692Form 174/11/20207/21/2020 81WATER H20 --0 NO FLOW 781781No----6 month follow-up test post abatement system install. PDC will continue to monitor pressure and report any increase in pressure to COGCC.
402034339Form 174/26/20195/7/2019FLOWING160DOWN TO 0 --0 NO FLOW 27112711No----160 PSI blew down to 0 PSI instantly, no flow or pressure for the remainder of bradenhead test. PDC will follow up with a sundry proposing a remediation plan for bradenhead pressure.
402016508Form 173/7/20194/22/2019SHUT-IN0NO FLOW --0 NO FLOW 00No----Post TD test, no pressure or fluid for duration of test
401613106Form 174/12/20184/18/2018SHUT-IN90DOWN TO 0 --0 NO FLOW 00No----Post TD test 90 PSI blew down to 0 PSI within first minute, no flow or pressure for remainder of test