Click for Specifics | Full | 7/31/2024 | 8/6/2024 | | 10 | Down to Zero | -- | 0 | No Flow | 386 | 392 | No | No | No | Annual Test. 10 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy. |
Click for Specifics | Full | 9/19/2023 | 9/25/2023 | Plunger Lift | 8 | Down to Zero | -- | 0 | Down to Zero | 389 | 382 | No | No | No | Annual Test. 8 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy. |
Click for Specifics | Full | 9/6/2022 | 10/10/2022 | | 42 | Down to Zero | -- | 0 | No Flow | 357 | 361 | No | None | None | |
Click for Specifics | Full | 4/15/2021 | 11/1/2021 | | 0 | No Flow | -- | 0 | No Flow | 515 | 516 | No | None | None | |
402610931 | Form 17 | 4/11/2020 | 2/25/2021 | | 49 | CONTINUOUS | WATER H20 | 0 | NO FLOW | 784 | 784 | No | -- | -- | Abatement system follow up test, 49 PSI blew down to 0 PSI within first min of test. No pressure or flow observed for the remainder of test. PDC will continue to monitor and re-test in 6 months. PDC will submit a sundry with well plans and flow rate information as soon as possible. |
402440677 | Form 17 | 3/29/2020 | 7/9/2020 | | 90 | DOWN TO 0 | -- | 0 | DOWN TO 0 | 804 | 801 | Yes | -- | -- | Annual Test 90 PSI with continuous flow, blew down to 0 PSI after 30 min. PDC has collected a sample and will submit via 43 ASAP. PDC will follow up with a remediation plan via sundry. |
402034096 | Form 17 | 4/25/2019 | 5/7/2019 | FLOWING | 112 | DOWN TO 0 | -- | 0 | NO FLOW | 2040 | 2040 | No | -- | -- | 112 PSI blew down to 0 PSI instantly, no flow or pressure for the remainder of bradenhead test. PDC will follow up with a sundry proposing a remediation plan for bradenhead pressure. |
401612969 | Form 17 | 4/12/2018 | 4/18/2018 | SHUT-IN | 100 | NO FLOW | -- | 0 | NO FLOW | 0 | 0 | No | -- | -- | Post TD test 100 PSI blew dow nto 0 PSI with no flow or pressure after first minute |