Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-123-44089Bunting
26P-232
PDC ENERGY INC
69175
PR
3/27/2019
WATTENBERG
90750
WELD  123
SWSE 26 5N65W 6
448963
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1642 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
Click for SpecificsFull7/31/20248/6/2024 10Down to Zero--0No Flow386392NoNoNoAnnual Test. 10 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull9/19/20239/25/2023Plunger Lift8Down to Zero--0Down to Zero389382NoNoNoAnnual Test. 8 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull9/6/202210/10/2022 42Down to Zero--0No Flow357361NoNoneNone 
Click for SpecificsFull4/15/202111/1/2021 0No Flow--0No Flow515516NoNoneNone 
402610931Form 174/11/20202/25/2021 49CONTINUOUS WATER H200 NO FLOW 784784No----Abatement system follow up test, 49 PSI blew down to 0 PSI within first min of test. No pressure or flow observed for the remainder of test. PDC will continue to monitor and re-test in 6 months. PDC will submit a sundry with well plans and flow rate information as soon as possible.
402440677Form 173/29/20207/9/2020 90DOWN TO 0 --0 DOWN TO 0 804801Yes----Annual Test 90 PSI with continuous flow, blew down to 0 PSI after 30 min. PDC has collected a sample and will submit via 43 ASAP. PDC will follow up with a remediation plan via sundry.
402034096Form 174/25/20195/7/2019FLOWING112DOWN TO 0 --0 NO FLOW 20402040No----112 PSI blew down to 0 PSI instantly, no flow or pressure for the remainder of bradenhead test. PDC will follow up with a sundry proposing a remediation plan for bradenhead pressure.
401612969Form 174/12/20184/18/2018SHUT-IN100NO FLOW --0 NO FLOW 00No----Post TD test 100 PSI blew dow nto 0 PSI with no flow or pressure after first minute