WELL05-123-43916Gillham
18Y-214
PDC ENERGY INC
69175
PR
10/16/2017
WATTENBERG
90750
WELD  123
SESE 18 5N64W 6
445032
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1665 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
Click for SpecificsLight4/22/20255/5/2025 0 --0 195203NoNoNo 
Click for SpecificsFull5/16/20245/30/2024 0Down to Zero--0Down to Zero152151NoNoNoAnnual Test.  0 PSI, with no pressure or flow observed for the entire 30-minute test.  PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull6/21/20236/28/2023 0Down to Zero--0Down to Zero187188NoNoNo 
Click for SpecificsFull5/26/20226/13/2022 5Down to Zero--0No Flow189189NoNoneNone 
Click for SpecificsFull6/1/202111/1/2021 0No Flow--0No Flow250250NoNoneNone 
402425466Form 172/21/20206/18/2020 2DOWN TO 0 --0 NO FLOW 423401No----6 month follow-up test post abatement system install. PDC will continue to monitor pressure and report any increase in pressure to COGCC.
402087685Form 174/30/20196/25/2019FLOWING110DOWN TO 0 --0 NO FLOW 683683No----Annual Test 110 PSI blew down to 0 PSI within minutes no pressure or flow after 30 min. PDC will attempt to collect a sample and will submit via 43 ASAP. PDC has submitted a remediation plan via sundry.
402077732Form 174/18/20196/17/2019SHUT-IN110WHISPER --0 WHISPER 683704No----Annual Test 110 PSI whisper blew down to 0 PSI after 30 min. PDC will attempt to collect a sample and will submit via 43 ASAP. PDC will follow up with a remediation plan via sundry.
401466347Form 1711/14/201711/21/2017FLOWING375CONTINUOUS --7 WHISPER 27182711YesYes--Post Production Test, 375 PSI blew down to 7 PSi, production and bradenhead gas sample collected and will be submitted to COGCC asap.
401348333Form 177/14/20177/20/2017SHUT-IN700DOWN TO 0 --0 NO FLOW 00No----Pre Completion Test initial pressure 700 PSI BLEED TO 0 PSI WITHIN seconds no flow for duration of test