Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-123-43914Gillham
18Y-314
PDC ENERGY INC
69175
PR
10/1/2024
WATTENBERG
90750
WELD  123
SESE 18 5N64W 6
445032
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1658 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
Click for SpecificsLight4/22/20255/5/2025 0 --0 216231NoNoNo 
Click for SpecificsFull5/16/20245/30/2024 0Down to Zero--0Down to Zero189183NoNoNoAnnual Test.  0 PSI, with no pressure or flow observed for the entire 30-minute test.  PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull6/21/20236/28/2023 0Down to Zero--0Down to Zero220219NoNoNo 
Click for SpecificsFull5/26/20226/13/2022 0No Flow--0No Flow206204NoNoneNone 
Click for SpecificsFull6/1/202111/1/2021 0No Flow--0No Flow230230NoNoneNone 
402425589Form 172/21/20206/18/2020 1DOWN TO 0 --0 NO FLOW 373369No----6 month follow-up test post abatement system install. PDC will continue to monitor pressure and report any increase in pressure to COGCC.
402088130Form 174/30/20196/26/2019FLOWING55DOWN TO 0 --0 NO FLOW 661661No----Annual Test 55 PSI whisper blew down to 0 PSI instantly no pressure or flow after 30 min test. PDC will attempt to collect a sample and will submit via 43 ASAP. PDC has submitted a remediationn plan via sundry
402078297Form 174/18/20196/18/2019SHUT-IN55WHISPER --0 WHISPER 661681No----Annual Test 55 PSI whisper blew down to 0 PSI after 30 min. PDC will attempt to collect a sample and will submit via 43 ASAP. PDC will follow up with a remediation plan via sundry.
401442384Form 1710/16/201710/26/2017FLOWING160WHISPER --0 NO FLOW 27262726No----Post Production Test, pressur blew down within first 5 minutes of test.
401348328Form 177/14/20177/20/2017SHUT-IN175DOWN TO 0 --0 NO FLOW 00No----Pre Completion Test initial pressure 175 PSI BLEED TO 0 PSI WITHIN seconds no flow for duration of test