Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-123-43902Gillham
18X-104
PDC ENERGY INC
69175
PR
10/17/2017
WATTENBERG
90750
WELD  123
SESE 18 5N64W 6
445032
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1675 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
Click for SpecificsLight4/22/20255/5/2025 30 --0 272273NoNoNo 
Click for SpecificsFull5/16/20245/30/2024 0Down to Zero--0Down to Zero212166NoNoNoAnnual Test.  0 PSI, with no pressure or flow observed for the entire 30-minute test.  PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull6/21/20236/28/2023 0Down to Zero--0Down to Zero200201NoNoNo 
Click for SpecificsFull5/26/20226/13/2022 0No Flow--0No Flow202202NoNoneNone 
Click for SpecificsFull4/20/202111/1/2021 1Down to Zero--0No Flow310307NoNoneNone 
Click for SpecificsLight6/8/202012/14/2020 0 --0 435435NoNoNo 
Click for SpecificsLight4/18/20198/18/2020 8 --0 701701NoNoNo 
401442232Form 1710/16/201710/26/2017SHUT-IN10WHISPER --0 NO FLOW 27262726No----Post Production test, pressure blew down within first minute of test, no sample collected.
401348309Form 177/14/20177/20/2017SHUT-IN200DOWN TO 0 --0 NO FLOW 00No----Pre Completion Test initial pressure 200 PSI BLEED TO 0 PSI WITHIN seconds no flow for duration of test