Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-123-43560Wacker
10G-302
PDC ENERGY INC
69175
PR
10/1/2023
WATTENBERG
90750
WELD  123
SWNW 10 5N64W 6
323125
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1668 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
Click for SpecificsFull5/15/20245/30/2024 0Down to Zero--0Down to Zero257258NoNoNoAnnual Test.  0 PSI, with no pressure or flow observed for the entire 30-minute test.  PDC will monitor pressure and re-test according to bradenhead policy.
403473962Form 177/24/20237/24/2023PLUNGER LIFT5WHISPER WATER AND GAS0 NO FLOW 288287No----Abatement System Follow-Up test. 5 PSI whisper gas and fluid blew down to 0 PSI in seconds. No flow or pressure for remainder of test. PDC will monitor pressure and re-test according to bradenhead policy.
403411481Form 175/23/20235/24/2023SHUT-IN78CONTINUOUS WATER AND GAS5 WHISPER 359359Yes----Annual test. 78 PSI water and gas flow on open, pressure blew down to 5 PSI in 30 minutes. PDC will collect a sample and submit results via form 43. PDC will monitor pressure and re-test according to bradenhead policy.
403153738Form 178/31/20229/1/2022PLUNGER LIFT120CONTINUOUS GAS AND LIQUID HYDROCARBON0 NO FLOW 309307Yes----Annual Test. 120 PSI gas and liquid hydrocarbon blew down to 0 PSI within first 5 minutes of test. No pressure or flow observed for the remainder of the test. PDC will schedule a sampling event and submit results via form 43 as well as a remediation plan via sundry as soon as possible. PDC will continue to monitor monthly.
402719489Form 175/30/20216/15/2021PLUNGER LIFT0NO FLOW --0  445445No----Abatement system follow up test. No pressure or flow observed. PDC will submit sundry with bradenhead details as soon as possible.
Click for SpecificsFull3/9/202111/1/2021 0No Flow--0No Flow552540NoNoneNone 
402564718Form 1712/16/202012/31/2020PLUNGER LIFT480WHISPER GAS0 NO FLOW 834834No----Abatement system follow up Test, 4805 PSI slight gas whisper blew down to 0 PSI within first 15 min of test. No pressure or flow observed for the remainder of the test. PDC will schedule a sampling event and submit results via form 43
402456037Form 174/25/20207/29/2020FLOWING190GAS --0 NO FLOW 568568No----abatement system follow up test, 190 PSI blew down to 0 PSI within first minute of test. no pressure or flow observed for remainder of test. PDC will attempt to collect sample and submit results if available. PDC will re-test in 6 months
402439221Form 174/5/20207/8/2020 195WHISPER --0 NO FLOW 569569Yes----Annual Test 195 PSI with continuous flow, blew down to 0 PSI after 30 min. PDC has collected a sample and will submit via 43 ASAP. PDC will follow up with a remediation plan via sundry.
402270235Form 1712/16/201912/23/2019FLOWING300GAS --0 NO FLOW 699698YesYes--Annual test 300 PSI slight gas flow blew down to 0 PSI after first 10 min of test, no pressure or flow observed for the remainder of the test. PDC has collected a sample and will submit results via form 43 when available. PDC will submit a remediaon plan via sundry.