Surface Casing Depth: 1559 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404545327Form 172/6/20262/13/2026PLUNGER LIFT250CONTINUOUS GAS0 NO FLOW 483480No---- 
404111601Form 172/20/20252/28/2025SHUT-IN293DOWN TO 0 WATER AND GAS0 NO FLOW 390390No----Remediation follow up test. 293 PSI blew down to 0 PSI within eight minutes of test. No pressure or flow observed for the remainder of the test. Operator will monitor pressure and re-test according to bradenhead policy.
403713571Form 173/8/20243/8/2024PLUNGER LIFT236DOWN TO 0 GAS0 NO FLOW 376366No----Annual test. 236 PSI gas flow blew down to 0 PSI in 2 minutes. No flow or pressure for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
403349885Form 173/15/20233/20/2023PLUNGER LIFT62DOWN TO 0 GAS0 NO FLOW 251250Yes----Annual Test. 62 PSI gas flow blew down to 0 PSI within first minute of test. No pressure or flow observed for the remainder of the test. PDC will schedule a sampling event and submit results via form 43. PDC will continue to monitor monthly.
Click for SpecificsFull3/15/20224/18/2022 21Down to Zero--0No Flow331333NoNoNo 
402816045Form 179/15/20219/20/2021PLUNGER LIFT14DOWN TO 0 WATER H200 NO FLOW 321315No----Abatement system follow up test, 14 PSI water flow blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will submit sundry with bradenhead details as soon as possible. PDC will continue to monitor monthly.
402789474Form 174/21/20218/24/2021PLUNGER LIFT12CONTINUOUS WATER H200 NO FLOW 417417No----Annual Test, 12 PSI water flow blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will continue to monitor monthly.
402425834Form 174/27/20206/18/2020 0WATER H20 --0 WHISPER 495495No----6 month follow-up test post abatement system install. PDC will continue to monitor pressure and report any increase in pressure to COGCC.
402239577Form 1711/7/201911/14/2019PLUNGER LIFT290CONTINUOUS --3 GAS 763763Yes----Annual Test 290 PSI with continous gas flow blew down to 3 PSI slight gas flow at the end of the 30 min test. PDC has collected a gas sample and will submit resulta via form 43 when available. PDC has submitted a remediation plan via sundry
401347345Form 177/2/20177/19/2017FLOWING675CONTINUOUS --20 CONTINUOUS 15091509Yes----Post Production Test. Initial pressure 675 PSI had continous flow for duration of test, production gas and bradenhead sample taken.
401236941Form 172/22/20173/20/2017SHUT-IN500GAS --0 NO FLOW 00No----