Skip to Main Content

Incident Search

 
BradenheadView Related Related View DocsDoc
 
Facility TypeFacility ID/
API
Facility Name/
Number
Operator Name/
Number
StatusField Name/
Number
LocationLocation ID
WELL05-123-43384Clark
14J-343
PDC ENERGY INC
69175
SI
12/1/2025
WATTENBERG
90750
WELD  123
NWNE 14 5N65W 6
323242
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1546 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
404590539Form 173/10/20263/23/2026SHUT-IN6DOWN TO 0 WATER AND GAS0 CONTINUOUS 44No----Remediation follow up test. 6 PSI gas and water, blew down to 0 within first few seconds, water continued for entire test. Operator will schedule a sampling event and submit results via form 43. Operator will monitor pressure and re-test according to bradenhead policy.
404111585Form 172/20/20252/28/2025SHUT-IN19DOWN TO 0 GAS0 NO FLOW 417417No----Remediation follow up test. 19 PSI blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. Operator will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull3/14/20244/1/2024 24Down to Zero--0No Flow284305NoNoNoAnnual Test.  24 PSI blew down to 0 PSI within first few seconds of test.  No pressure or flow observed for the remainder of the test. PDC will monitor pressure and re-test according to bradenhead policy.
Click for SpecificsFull3/17/20233/27/2023 0No Flow--0No Flow229239NoNoneNoneAnnual Test. 0 PSI, with no pressure or flow observed for the entire 30-minute test. PDC will continue to monitor monthly.
403216538Form 1711/1/202211/2/2022PLUNGER LIFT20DOWN TO 0 GAS0 NO FLOW 259260No----Abatement system follow up test. 20 PSI gas flow blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will submit sundry with bradenhead details as soon as possible. PDC will continue to monitor monthly.
402984421Form 173/14/20223/15/2022PLUNGER LIFT93CONTINUOUS GAS0 WHISPER 339339Yes----Annual Test, 93 PSI continuous whisper gas flow blew down to 0 PSI within 30 minutes. PDC will schedule a sampling event and submit results via form 43 as well as a remediation plan via sundry as soon as possible. PDC will continue to monitor monthly.
402815993Form 179/15/20219/20/2021PLUNGER LIFT37DOWN TO 0 GAS0 NO FLOW 340337No----Abatement system follow up test, 37 PSI gas blew down to 0 PSI within first few seconds of test. No pressure or flow observed for the remainder of the test. PDC will submit sundry with bradenhead details as soon as possible. PDC will continue to monitor monthly.
402670338Form 174/21/20214/26/2021 117WHISPER GAS0 NO FLOW 586586Yes----Annual Test 137 PSI with continuous flow, blew down to 0 PSI after 30 min. PDC has collected a sample and will submit via 43 ASAP. PDC will follow up with a remediation plan via sundry.
402425827Form 174/27/20206/18/2020 0WHISPER --0 WHISPER 671671No----6 month follow-up test post abatement system install. PDC will continue to monitor pressure and report any increase in pressure to COGCC.
402236396Form 1711/7/201911/12/2019PLUNGER LIFT288GAS --27 WHISPER 757757YesYes--Annual TEst, 288 PSI slight gas flow blew down to a whisper for the duration of the 30 min test. 27 PSI at the end of the test. PDC has collected a sample and will submit results via form 43. PDC will submit a remediation plan via sundry.
401347319Form 177/2/20177/19/2017FLOWING80CONTINUOUS --0 NO FLOW 19701969No----Post Production test, intitial pressure 80 PSI gradually bled down to 0 PSI no flow for duration of test
401237234Form 172/22/20173/20/2017SHUT-IN700VAPOR --0 NO FLOW 00No----Initial pressure of 700 psi dropped to 250 psi within the first 5 minutes of test, then decreased to zero within 10 minutes.