WELL05-123-43302Morgan Hills
1G-7H-A168
CRESTONE PEAK RESOURCES OPERATING LLC
10633
PR
5/1/2021
WATTENBERG
90750
ERIE/WELD  123
NENE 7 1N68W 6
446290
   
Search for Different Bradenhead:
County Code: Sequence Code:
 
Surface Casing Depth: 1773 ft.
View Form/DetailsReport TypeTest DateSubmit DateWell StatusInitial Surf CasingBradenhead Flow (Start)Fluid TypeEnd Surf CasingBradenhead Flow (End)Initial Prod CasingEnd Prod CasingSample Taken?GasLiquidComments
403880195Form 178/5/20248/8/2024FLOWING64CONTINUOUS GAS0 NO FLOW 649658YesYes--Mitigation Bradenhead Test WBD submitted on doc# 403308115
403540420Form 179/22/20239/26/2023FLOWING71CONTINUOUS GAS0 NO FLOW 631638No----Mitigation Bradenhead Test WBD submitted on doc# 403308115
403364820Form 174/3/20234/4/2023FLOWING136CONTINUOUS GAS0 NO FLOW 668647No----Mitigation Bradenhead Test WBD submitted on doc# 403308115
Click for SpecificsLight4/28/20225/16/2022Flowing0 --0 786787NoNoNo 
Click for SpecificsLIGHT7/16/20217/27/2021Flowing-3 --0 13021302NoNoNo 
Click for SpecificsLight7/1/20207/20/2020 -6 --0No Flow730729NoNoNo 
402004588Form 173/25/20194/15/2019FLOWING-5WHISPER --0 NO FLOW 820820No----Test results are being submitted via Form 17 in order to demonstrate the completion of bradenhead test per Order No. 1V. 687 - Order 4.b., since the annual test upload tool is not yet available. Bradenhead pressure less than 50 psig, no continuous liquid or gas flow, so Form 17 submission is not required per NTO annual test requirements.
401591506Form 173/28/20183/29/2018SHUT-IN0NO FLOW --0 NO FLOW 15751614No----post stim test